66
Care and maintenance
T
IP
To check again
> Set the system under pressure to 100 bar (1450.4 psi)
> Repeat the checking procedure.
After checking
> Set the pressure of the system to 100–160 bar (1450.4- 2320.6
psi), depending on the conditions on the ground
> Disconnect the filling hose from the quick connection on the accu
-
mulator
> Disconnect the filling hose from the tractor
> Refit the dust covers
Refilling
Refilling must be carried out at a special service station.
•
Refill the accumulator when the preload pressure falls below 80
bar (1160.3 psi).
•
Refill the accumulator with nitrogen to 90 bar (1305.3 psi).
Hose for oil refilling to
the tractor
Quick connections
Ram
free to move
Gas valve
Do not touch
Min 100 bar (1450.4 psi)
Max 160 bar (2320.6 psi)