![Kverneland Electrical Control EC Скачать руководство пользователя страница 51](http://html.mh-extra.com/html/kverneland/electrical-control-ec/electrical-control-ec_operation-manual_2012934051.webp)
Control box
Flowmate Control FMC
51
§5.27 T
ROUBLESHOOTING
T
ABLE
Possible faults
Check
Wheel sensor, through flow sensor
do not work
-
Is a voltage of 12 V available on the connection jack of the
SHC box for the sensor?
1)
-
Is the LED of the sensor on? (N/A for through flow sensor.)
-
Check input signal on the SHC box?
1)
-
Does the sensor work in test operation?
-
Are all the wires connected correctly?
Pressure sensor does not work
-
Is a voltage of 5/12 V available on the connection jack of
the SHC box for the sensor?
1)
-
Are all the wires connected correctly?
Faulty display of the driving speed
-
Does the sensor work? Is the setting correct?
-
Is the wheel/radar setting correct?
-
Calibration done correctly?
-
Does the system work at simulation speed?
Faulty display of the through flow
-
Does the sensor work?
-
Is the computer set to "through flow quantity"?
-
Calibration done correctly?
No transmission of data
-
Does the energy supply work?
-
Are all the wires connected correctly?
-
Does the Run LED on the motherboard of the SHC box
flash?
1)
-
Does the Run LED on the motherboard of the control box
flash?
1)
Faulty display of the pressure
-
Does the sensor work?
-
Calibration done correctly?
Sections cannot be switched via
the control box
-
Are all the wires connected correctly?
-
Does the Run LED on the motherboard of the SHC box
flash?
1)
-
Is the switch of the control box set to “ON”?
-
Check output signal of the SHC box?
1)
-
Does the output work in test operation?
Malfunction of the through flow
regulation
-
Does the speed sensor work correctly?
-
Do the through flow and pressure sensors work correctly?
-
Is the "Through flow quantity/Pressure" setting correct?
-
Does the system work at simulation speed?
-
Does the pressure regulator working correctly?
-
Are all the settings correct?
-
Have all the calibration processes been done correctly?
Filling/rinsing function is not
implemented correctly
-
Are all the settings for filling/rinsing function correct?
-
Is the "Filling/rinsing function" setting correct?
Difference between nominal and
actual value of the application rate
-
Does the pressure regulator work without faults?
-
Does the through flow sensor work without faults?
!S
Alarm top left of display
-
No connection to the section valve block
!H
Alarm top left of display
-
No connection to the hydraulic valve block
1)
All checks, which have to be made on the motherboard on the inside of the SHC box or
control box may only be done by personnel with matching training!
Содержание Electrical Control EC
Страница 6: ...Spray computer FMC EC GZD EC OPERATING INSTRUCTIONS 6 ...
Страница 15: ...System overview and assembly Flowmate Control FMC 15 Fig 4 Fig 5 6 9 5 7 6 8 ...
Страница 17: ...System overview and assembly Flowmate Control FMC 17 Fig 6 Fig 7 Fig 8 Fig 9 10 10 11 10 12 14 6 13 ...
Страница 19: ...Control box Flowmate Control FMC 19 Fig 1 4 1 5 3 3 6 2 Fig 2 8 9 7 ...
Страница 21: ...Control box Flowmate Control FMC 21 Fig 4 11 Fig 3 10 ...
Страница 37: ...Control box Flowmate Control FMC 37 ...
Страница 55: ...Control box Electrical Control EC 55 Fig 1 2 3 4 Fig 2 blue brown Fig 3 30 4 5 m 25 cm 5 30 A fuse pole pole ...
Страница 57: ...Control box Electrical Control EC 57 25 Amp Fig 2 4 1 5 3 3 2 Fig 1 Fig 3 7 8 6 ...
Страница 59: ...Control box Electrical Control EC 59 Fig 5 10 Fig 4 9 ...
Страница 61: ...Electrical Control GZD EC Electrical Control GZD EC 61 ELECTRICAL CONTROL GZD EC ...
Страница 65: ...Electrical Control GZD EC Electrical Control GZD EC 65 Fig 3 5 6 7 8 10 9 11 Fig 4 i 13 12 ...
Страница 67: ...Electrical Control GZD EC Electrical Control GZD EC 67 Fig 5 14 Fig 6 5 6 7 8 10 9 ...
Страница 68: ...Notes OPERATING INSTRUCTIONS 68 ...