Flowmate Control FMC
OPERATING INSTRUCTIONS
42
The upper value corresponds to the number of impulses matching the lower value, the measured
distance
If the impulse values for a certain measurement distance is already known, the two values,
measurement distance and matching number of impulses, can be input directly (e.g. change of
tractors in joint use of machines).
If the driving speed has to be calibrated, please proceed as follows:
-
A measurement distance, for example 100 metres, is precisely set.
-
At the start of the measurement distance, press arrow key , the calibration process is started,
a signal sounds.
-
Run along the measurement distance and press the
OK key
at the end, the measurement
distance flashes.
-
Confirm the measurement distance with the
OK key
.
If the measurement distance set does not correspond to the lower value in the display, change the
value in the display accordingly.
Note:
The calibration run should be done on a field with the spray tank half full. In this way, errors
by slip, subsiding wheels etc. are reduced to a minimum.
§5.11 C
ALIBRATION OF THE DRIVING SPEED
(
WITH RADAR
)
If the driving speed is measured by a radar sensor on the tractor, the calibration is done in
Screen
13
.
The number of impulses must be entered manually according to the information in the operating
instructions for the tractor. (basic setting = 130 impulses)
§5.12 C
ALIBRATION OF THE FLOWMETER
Screen 14
contains the calibration of the flow meter.
To calculate the through flow in l/min the spraying computer needs the ratio of numbers of
impulses to litres. The number of impulses per litre is stated on the flow meter.
To calibrate the flow meter, the number of impulses (e.g. 641 pls/l) is to be input in
Screen 12
(as
the bottom value). We recommend checking this value annually (best of all before the spraying
season) by "gauging by litres".
To "gauge by litres" only clear water may be used and the spraying system must be cleaned
thoroughly beforehand (see operating instructions spraying system).
Mode of procedure in "gauging":
-
Fill the sprayer with clear water and set all operating elements to
“Spraying”
.
-
Switch the power take-off shaft on and allow to run at 540 rpm.
-
On the control box, switch all section switches to
“On”
.
-
Central switch
Spraying
to
“On”
.
Содержание Electrical Control EC
Страница 6: ...Spray computer FMC EC GZD EC OPERATING INSTRUCTIONS 6 ...
Страница 15: ...System overview and assembly Flowmate Control FMC 15 Fig 4 Fig 5 6 9 5 7 6 8 ...
Страница 17: ...System overview and assembly Flowmate Control FMC 17 Fig 6 Fig 7 Fig 8 Fig 9 10 10 11 10 12 14 6 13 ...
Страница 19: ...Control box Flowmate Control FMC 19 Fig 1 4 1 5 3 3 6 2 Fig 2 8 9 7 ...
Страница 21: ...Control box Flowmate Control FMC 21 Fig 4 11 Fig 3 10 ...
Страница 37: ...Control box Flowmate Control FMC 37 ...
Страница 55: ...Control box Electrical Control EC 55 Fig 1 2 3 4 Fig 2 blue brown Fig 3 30 4 5 m 25 cm 5 30 A fuse pole pole ...
Страница 57: ...Control box Electrical Control EC 57 25 Amp Fig 2 4 1 5 3 3 2 Fig 1 Fig 3 7 8 6 ...
Страница 59: ...Control box Electrical Control EC 59 Fig 5 10 Fig 4 9 ...
Страница 61: ...Electrical Control GZD EC Electrical Control GZD EC 61 ELECTRICAL CONTROL GZD EC ...
Страница 65: ...Electrical Control GZD EC Electrical Control GZD EC 65 Fig 3 5 6 7 8 10 9 11 Fig 4 i 13 12 ...
Страница 67: ...Electrical Control GZD EC Electrical Control GZD EC 67 Fig 5 14 Fig 6 5 6 7 8 10 9 ...
Страница 68: ...Notes OPERATING INSTRUCTIONS 68 ...