![Kverneland Electrical Control EC Скачать руководство пользователя страница 43](http://html.mh-extra.com/html/kverneland/electrical-control-ec/electrical-control-ec_operation-manual_2012934043.webp)
Control box
Flowmate Control FMC
43
-
On the spraying computer, select
Screen 14
in the
Setting menu
, the current through flow
quantity and impulse value are displayed (see above).
-
After this, the nozzle output is to be determined with at least 5 nozzles distributed across the
entire width of the spray boom by using a measurement vessel.
-
The values are averaged and calculated by multiplication with the number of nozzles of the
overall output of the spray boom.
-
If the determined overall output in l/min does not match the l/min display value, the value shown
in the display must be corrected according and confirmed with the
OK key
.
Important Note:
The power take-off shaft speed and the pressure regulator may not be altered
during the entire sequence (from collecting the fluid up to and including the
correction of the l/min value)!
§5.13 S
IMULATION SPEED
Screen 15
is used to set the simulation speed.
The simulation speed ought if possible to be the speed at which spraying is normally done. This
prevents the system from regulating the pressure down if the vehicle is still stationary for a short
time at the edge of the field at the start of spraying.
The simulation speed is automatically used as a substitute value if the central switch is set to
“Spraying”
and no speed signal is available, e.g. in a defect of the speed sensor or in "gauging"
of the spraying system if the vehicle is stationary.
The simulation speed is also used for the anticipation regulation (
Screen 21
).
§5.14 E
DGE NOZZLES
Screen 16
is used to set how the two outer switches (3) on the control box (see fig. 1, page 19) are
used.
The following 2 possibilities exist:
a) Use of edge nozzles for precise field-edge spraying:
-
In this case, the two outer switches (3) (fig. 1, page 19) are used to switch between the outer
nozzle and the edge nozzle. The edge nozzle has an asymmetric spraying image, the
spraying angle towards the edge of the field is smaller, resulting in a sharper demarcation of
the working width.
-
The working width of the spray boom is not altered in the switch-over.
-
In the programming of the sections (Screens 17/19) no working width can be programmed for
the two outer switches L5 and R5 in this case.
In
Screen 16
select the pictogram with
X
.
Содержание Electrical Control EC
Страница 6: ...Spray computer FMC EC GZD EC OPERATING INSTRUCTIONS 6 ...
Страница 15: ...System overview and assembly Flowmate Control FMC 15 Fig 4 Fig 5 6 9 5 7 6 8 ...
Страница 17: ...System overview and assembly Flowmate Control FMC 17 Fig 6 Fig 7 Fig 8 Fig 9 10 10 11 10 12 14 6 13 ...
Страница 19: ...Control box Flowmate Control FMC 19 Fig 1 4 1 5 3 3 6 2 Fig 2 8 9 7 ...
Страница 21: ...Control box Flowmate Control FMC 21 Fig 4 11 Fig 3 10 ...
Страница 37: ...Control box Flowmate Control FMC 37 ...
Страница 55: ...Control box Electrical Control EC 55 Fig 1 2 3 4 Fig 2 blue brown Fig 3 30 4 5 m 25 cm 5 30 A fuse pole pole ...
Страница 57: ...Control box Electrical Control EC 57 25 Amp Fig 2 4 1 5 3 3 2 Fig 1 Fig 3 7 8 6 ...
Страница 59: ...Control box Electrical Control EC 59 Fig 5 10 Fig 4 9 ...
Страница 61: ...Electrical Control GZD EC Electrical Control GZD EC 61 ELECTRICAL CONTROL GZD EC ...
Страница 65: ...Electrical Control GZD EC Electrical Control GZD EC 65 Fig 3 5 6 7 8 10 9 11 Fig 4 i 13 12 ...
Страница 67: ...Electrical Control GZD EC Electrical Control GZD EC 67 Fig 5 14 Fig 6 5 6 7 8 10 9 ...
Страница 68: ...Notes OPERATING INSTRUCTIONS 68 ...