Calibrating the Feelers
4-7
KVAL Operation Manual
Calibrating the Feelers
Process
:
1.
Measure a known good door.
a.The door should be true and be considered a calibration reference
b. Door should be sturdy enough to survive multiple passes through machine.
c..Capture the width, length, and thickness measurements. (These measure-
ments are used to compare feed backs from the encoders.)
4.
After the door has been fed in, Check the measurements fed back from the encoders
a.. Select the
Log Tab
from the
Edge-SS Screen
check the latest feedback from
encoder.
5.
Get averages of the feedback. Capture the measurements.
a.Run the door and re-feed it at least 3 times. (Each time capturing the measure-
ments from the Log Screen)
b.Reverse the door and re-feed it at least 3 times. Repeat data collection.
6.
Compute the averages of the fed-back measurement.
7.
Enter the data derived from the averages
a.Go to the
Edge-SS Calibration
, select
Feelers-
b.Subtract measured data to adjust for the difference
Door Feelers
is the first calibration that should be checked or
performed. This calibration adjusts the encoders located in
the machine. These calibrations are a starting reference for all
calibrations.
2.
Ensure the
Set-Up Mode
is Enabled (no cut-
ting).
a.Select the
Edge-SS
-
Main Control Tab
and
under the
Main Control Section
select the
Setup Mode
button.
3.
Feed a Test Door into the machine.
Содержание Edge-SS
Страница 4: ...KVAL Edge SS System Operation Manual ...
Страница 6: ...KVAL Edge SS System Operation Manual ...
Страница 12: ...KVAL Edge SS Manual Table of Contents ...
Страница 32: ...How to Download the Service Application KVAL Operation Manual 1 20 Page Intentionally Left Blank ...
Страница 49: ...About Revisions 2 16 KVAL Manual ...
Страница 84: ...Common Terms 2 51 KVAL Manual FIGURE 2 11 Example of a Validation Report ...
Страница 147: ...About the Nodes 5 21 KVAL Operation Manual ...
Страница 149: ...Index Kval Edge SS clean up 12 inspect 12 ...
Страница 150: ......
Страница 151: ......