RESISTANCE
Range
Accuracy
Resolution
200
W
2 K
W
20 K
W
200 K
W
2 M
W
20 M
W
200 M
W
0.01
W
0.1
W
1
W
10
W
100
W
1 K
W
10 K
W
Overload protection : 250V, DC or AC peak value.
Open circuit Voltage : <1V
(2.8V in the 200M
W
position).
Note : It is normal that the test lead short-circuit
displays approx. 10 digits in the 200M
W
position. Please deduct these 10 digits from
reading when measuring.
±(0.2% + 5)
CAPACITANCE
Range
Accuracy
Resolution
2 nF
20 nF
200 nF
0.1 pF
1 pF
10 pF
100 pF
10 nF
±(5% + 3)
Frequency measurement : Approx 400Hz.
Voltage measurement : Approx 40mV.
±(2.5% + 10)
±(0.5% + 10)
±(0.5% + 5)
±(0.2% + 1)
2
m
F
200
m
F
6
FREQUENCY
Range
Accuracy
Resolution
20 kHz
1Hz
Voltage Protection : 250V DC or AC peak value.
Input sensitivity : 150 mV RMS.
±(2% + 5)
TRIODE HFE PARAMETER MEASUREMENT
Range
Description
Test Condition
hFE
1b approx
10
m
A,
Vec approx
2.8V
It can measure NPN or
PNP type transistor
triode hFE parameter.
Indication range:0-1000
b
DIODE AND CONTINUITY MEASUREMENT
Range
Description
Test Condition
Forward-way
current is approx
1mA, contray-
way voltage is
approx 2.8V
Indicate approx
forward voltage
drop of diode
The buzzer inside
sounds when
continuity
Resistance is
<30
W
Open Circuit
Voltage is
approx 2.8V
Overload protection :
250V DC or AC peak value.
7