background image

RESISTANCE

Range

Accuracy

Resolution

200     

W

2      K

W

20    K

W

200  K

W

2      M

W

20    M

W

200  M

W

0.01   

W

0.1     

W

1        

W

10      

W

100    

W

1      K

W

10    K

W

Overload protection : 250V, DC or AC peak value.
Open circuit Voltage : <1V
                                 (2.8V in the 200M

W

 

position).

Note : It is normal that the test lead short-circuit 
          displays approx. 10 digits in the 200M

W

 

          position.  Please deduct these 10 digits from 
          reading when measuring.

±(0.2% + 5)

CAPACITANCE

Range

Accuracy

Resolution

2       nF

20     nF

200   nF

0.1   pF

1      pF

10    pF

100  pF

10    nF

±(5% + 3)

Frequency measurement : Approx 400Hz.

Voltage measurement : Approx 40mV.

±(2.5% + 10)

±(0.5% + 10)

±(0.5% + 5)

±(0.2% + 1)

2       

m

F

200   

m

F

6

FREQUENCY

Range

Accuracy

Resolution

20 kHz

1Hz

Voltage Protection : 250V DC or AC peak value.

Input sensitivity : 150 mV RMS.

±(2% + 5)

TRIODE HFE PARAMETER MEASUREMENT

Range

Description

Test Condition

hFE

1b approx

10

m

A,

Vec approx

2.8V

It can measure NPN or 

PNP type transistor 

triode hFE parameter.

Indication range:0-1000 

b

DIODE AND CONTINUITY MEASUREMENT

Range

Description

Test Condition

Forward-way

current is approx

1mA, contray-

way voltage is

approx 2.8V

Indicate approx

forward voltage

drop of diode

The buzzer inside 

sounds when

continuity 

Resistance is 

<30 

W

Open Circuit

Voltage is 

approx 2.8V

Overload protection :

 250V DC or AC peak value.

7

Содержание KM 6050

Страница 1: ...alog Digital Insulation Resistance Testers upto 10 KV Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Thermo Hygro...

Страница 2: ...we damage them or burn them out If you incorrectly...

Страница 3: ...cient protection for the Function Range switch You can select different models to measure DCV DCA ACV ACA Resistance Capacitance Frequency Temperature Diode hFE and Continuity This type can be applied...

Страница 4: ...could result in serious injury or even death to the user Terms in this manual Low power consumption CMOS double integration A D transform integrated circuit Auto zero Calibration Auto polarity displa...

Страница 5: ...Frequency Range 40Hz 400Hz Overload protection 250V for 200mV DC or AC peak value 1000V for other ranges Display Average value Sine RMS 4 DC CURRENT Range Accuracy Resolution 2 mA 20 mA 200 mA 20 A 10...

Страница 6: ...ge measurement Approx 40mV 2 5 10 0 5 10 0 5 5 0 2 1 2 m F 200 m F 6 FREQUENCY Range Accuracy Resolution 20 kHz 1Hz Voltage Protection 250V DC or AC peak value Input sensitivity 150 mV RMS 2 5 TRIODE...

Страница 7: ...d Danger High Voltage 8 9 COM VW Hz 20A mA NPN B B E E E PNP E C C Cx 6 MULTIMETER STRUCTURE 4 5 6 1 7 2 3 8 1 LCD display 2 Function range selection 3 Test lead jack 4 Power switch 5 Triode measureme...

Страница 8: ...1000 200 20 V 2 2n 20n 200n 2m 200m 2m 20m 200m 20 20 200m 20m 2m A hFE 20kHz A W F 10 2 AC Voltage Measurement 1 Set the function range switch on ACV range 2 Insert the black test lead into COM jack...

Страница 9: ...2 Insert the black test lead into COM jack and the red test lead into the exposed test lead jack mA jack or 20A jack Connect the test lead to the tested circuit in series Supply Load Remark A Refer t...

Страница 10: ...he positive polarity of the measurement circuit Connect the test lead to the two ends of the tested resistance 15 6 Capacitance measurement 1 Set the function range switch on the range position needed...

Страница 11: ...surement unit 1pF 10 m F 1nF 10 m F D Don t insert the capacitors with high voltage into the test jack direct 17 B If the tested signal is too strong you should use the external attenuation so as not...

Страница 12: ...NPN B B E E E PNP E C C Cx KM 6050 POWER LIGHT HOLD Auto Power off 200 2K 20K 200K 2M 20M 200M 200m 2 V 20 200 1000 1000 200 20 V 2 2n 20n 200n 2m 200m 2m 20m 200m 20 20 200m 20m 2m A hFE 20kHz A W F...

Страница 13: ...tion 2 Insert the black test lead into COM socket and the red one into VW Hz jack and connect the test lead to the two ends of the circuit to be tested Remark You must cut off the power before you che...

Страница 14: ...test leads from the input terminals Remove the back cover screws and open the back cover Replace the fuse fuses with new fuse of the same type and rating 0 2A 250V 6 Remove the battery and put it in a...

Страница 15: ...ntees that the product has been inspected and tested in accordance with the published specifications The instrument has been calibrated by using equipment which has already been calibrated to standard...

Страница 16: ...ed dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty...

Отзывы: