background image

WARRANTY

26

Each  “KUSAM-MECO”  product  is  warranted  to  be 

free  from  defects  in  material  and  workmanship 

under normal use & service.  The warranty period is 

one year (12 months) and begins from the date of 

despatch  of  goods.    In  case  any  defect  occurs  in 

functioning  of  the  instrument,  under  proper  use, 

within the warranty period, the same will be rectified 

by us free of charges, provided the to and fro freight 

charges are borne by you.

This warranty extends only to the original buyer or 

end-user customer of a “KUSAM-MECO” authorized 

dealer.

This  warranty  does  not  apply  for  damaged  Ic’s, 

fuses,  burnt  PCB's,  disposable  batteries,  carrying 

case, test leads, or to any product which in “KUSAM-

MECO’s”  opinion,  has  been  misused,  altered, 

neglected, contaminated or damaged by accident or 

abnormal conditions of operation or handling.

“KUSAM-MECO” authorized dealer shall extend this 

warranty on new and unused products to end-user 

customers  only  but  have  no  authority  to  extend  a 

greater or different warranty on behalf of “KUSAM-

MECO”.

“KUSAM-MECO’s” warranty obligation is limited, at 

option,  free  of  charge  repair,  or  replacement  of  a 

defective product which is returned to a “KUSAM-

MECO”  authorized  service  center  within  the 

warranty period.

G 17,Bharat Industrial Estate, T. J. Road, 
Sewree (W), Mumbai - 400 015. INDIA.

Sales Direct :

 (022) 24156638

Tel. :

 (022) 24124540, 24181649.

Fax :

 (022) 24149659

Email :

 [email protected]

Website :

 www.kusamelectrical.com, 

                 www.kusam-meco.co.in

THIS  WARRANTY  IS  BUYER’S  SOLE  AND 

EXCLUSIVE  REMEDY AND  IS  IN  LIEU  OF ALL 

OTHER WARRANTIES, EXPRESS OR IMPLIED, 

INCLUDING BUT NOT LIMITED TO ANY IMPLIED 

WARRANTY  OF  MERCHANTABILITY  OR 

FITNESS  FOR  A  PARTICULAR  PURPOSE.   

“KUSAM-MECO”  SHALL  NOT  BE  LIABLE  FOR 

ANY  SPECIAL,  INDIRECT,  INCIDENTAL  OR 

CONSEQUENTIAL  DAMAGES  OR  LOSSES, 

INCLUDING  LOSS  OF  DATA,  ARISING  FROM 

ANY CAUSE WHATSOEVER.

All transaction are subject to Mumbai Jurisdiction.

27

Содержание KM 6050

Страница 1: ...alog Digital Insulation Resistance Testers upto 10 KV Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Thermo Hygro...

Страница 2: ...we damage them or burn them out If you incorrectly...

Страница 3: ...cient protection for the Function Range switch You can select different models to measure DCV DCA ACV ACA Resistance Capacitance Frequency Temperature Diode hFE and Continuity This type can be applied...

Страница 4: ...could result in serious injury or even death to the user Terms in this manual Low power consumption CMOS double integration A D transform integrated circuit Auto zero Calibration Auto polarity displa...

Страница 5: ...Frequency Range 40Hz 400Hz Overload protection 250V for 200mV DC or AC peak value 1000V for other ranges Display Average value Sine RMS 4 DC CURRENT Range Accuracy Resolution 2 mA 20 mA 200 mA 20 A 10...

Страница 6: ...ge measurement Approx 40mV 2 5 10 0 5 10 0 5 5 0 2 1 2 m F 200 m F 6 FREQUENCY Range Accuracy Resolution 20 kHz 1Hz Voltage Protection 250V DC or AC peak value Input sensitivity 150 mV RMS 2 5 TRIODE...

Страница 7: ...d Danger High Voltage 8 9 COM VW Hz 20A mA NPN B B E E E PNP E C C Cx 6 MULTIMETER STRUCTURE 4 5 6 1 7 2 3 8 1 LCD display 2 Function range selection 3 Test lead jack 4 Power switch 5 Triode measureme...

Страница 8: ...1000 200 20 V 2 2n 20n 200n 2m 200m 2m 20m 200m 20 20 200m 20m 2m A hFE 20kHz A W F 10 2 AC Voltage Measurement 1 Set the function range switch on ACV range 2 Insert the black test lead into COM jack...

Страница 9: ...2 Insert the black test lead into COM jack and the red test lead into the exposed test lead jack mA jack or 20A jack Connect the test lead to the tested circuit in series Supply Load Remark A Refer t...

Страница 10: ...he positive polarity of the measurement circuit Connect the test lead to the two ends of the tested resistance 15 6 Capacitance measurement 1 Set the function range switch on the range position needed...

Страница 11: ...surement unit 1pF 10 m F 1nF 10 m F D Don t insert the capacitors with high voltage into the test jack direct 17 B If the tested signal is too strong you should use the external attenuation so as not...

Страница 12: ...NPN B B E E E PNP E C C Cx KM 6050 POWER LIGHT HOLD Auto Power off 200 2K 20K 200K 2M 20M 200M 200m 2 V 20 200 1000 1000 200 20 V 2 2n 20n 200n 2m 200m 2m 20m 200m 20 20 200m 20m 2m A hFE 20kHz A W F...

Страница 13: ...tion 2 Insert the black test lead into COM socket and the red one into VW Hz jack and connect the test lead to the two ends of the circuit to be tested Remark You must cut off the power before you che...

Страница 14: ...test leads from the input terminals Remove the back cover screws and open the back cover Replace the fuse fuses with new fuse of the same type and rating 0 2A 250V 6 Remove the battery and put it in a...

Страница 15: ...ntees that the product has been inspected and tested in accordance with the published specifications The instrument has been calibrated by using equipment which has already been calibrated to standard...

Страница 16: ...ed dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty...

Отзывы: