1. GENERAL DESCRIPTION

KM 6050 Digital Multimeter is featured with precise 
design,  convenient  operation,  high  performance 
multifunction, a new protection holster and big LCD 
display.   To avoid improper operation, the current 
jack applies mechanical protection device.   Only 
when you select current measurement, the mA or 
20A jack is open accordingly.   Otherwise this jack 
is  closed  to  avoid  inserting  the  test  lead  wrong.   
“V

W

  Hz”  is  equipped  with  PTC  heat  sensitive 

element at the input terminal and this has efficient 
protection  for  the  Function  /  Range  switch.   You 
can select different models to measure DCV, DCA, 
ACV, ACA, Resistance, Capacitance, Frequency, 
Temperature,  Diode,  hFE  and  Continuity.    This 
type  can  be  applied  in  engineering  project, 
experiment test, production test work in the open 
air, and electrical repairs, etc.

2. SAFETY PRECAUTIONS AND PROCEDURES

1) For your own safety and that of the apparatus, 

you  must  read  and  follow  the  procedure 
described in this instruction manual.

2) Never use the instrument before replacing the 

back  cover,  or  having  the  risk  of  electronic 
shock.

3) If  any  unusual  condition  of  testing  end  and 

attachment  of  the  meter  such  as  breakage, 
deformation,  fracture,  foreign  substance,  no 
display, etc, do not conduct any measurement.

4) You  must  first  take  out  the  test  leads  before 

changing  to  different  current  measuring 
positions  and  then  turn  the  function  /  range 
switch  so  as  to  avoid  damaging  mechanical 
protection device.

1

Содержание KM 6050

Страница 1: ...alog Digital Insulation Resistance Testers upto 10 KV Digital Sound Level Meter Sound Level Calibrator Digital contact Non contact Type Tachometer Digital Non contact infrared Thermometer Thermo Hygro...

Страница 2: ...we damage them or burn them out If you incorrectly...

Страница 3: ...cient protection for the Function Range switch You can select different models to measure DCV DCA ACV ACA Resistance Capacitance Frequency Temperature Diode hFE and Continuity This type can be applied...

Страница 4: ...could result in serious injury or even death to the user Terms in this manual Low power consumption CMOS double integration A D transform integrated circuit Auto zero Calibration Auto polarity displa...

Страница 5: ...Frequency Range 40Hz 400Hz Overload protection 250V for 200mV DC or AC peak value 1000V for other ranges Display Average value Sine RMS 4 DC CURRENT Range Accuracy Resolution 2 mA 20 mA 200 mA 20 A 10...

Страница 6: ...ge measurement Approx 40mV 2 5 10 0 5 10 0 5 5 0 2 1 2 m F 200 m F 6 FREQUENCY Range Accuracy Resolution 20 kHz 1Hz Voltage Protection 250V DC or AC peak value Input sensitivity 150 mV RMS 2 5 TRIODE...

Страница 7: ...d Danger High Voltage 8 9 COM VW Hz 20A mA NPN B B E E E PNP E C C Cx 6 MULTIMETER STRUCTURE 4 5 6 1 7 2 3 8 1 LCD display 2 Function range selection 3 Test lead jack 4 Power switch 5 Triode measureme...

Страница 8: ...1000 200 20 V 2 2n 20n 200n 2m 200m 2m 20m 200m 20 20 200m 20m 2m A hFE 20kHz A W F 10 2 AC Voltage Measurement 1 Set the function range switch on ACV range 2 Insert the black test lead into COM jack...

Страница 9: ...2 Insert the black test lead into COM jack and the red test lead into the exposed test lead jack mA jack or 20A jack Connect the test lead to the tested circuit in series Supply Load Remark A Refer t...

Страница 10: ...he positive polarity of the measurement circuit Connect the test lead to the two ends of the tested resistance 15 6 Capacitance measurement 1 Set the function range switch on the range position needed...

Страница 11: ...surement unit 1pF 10 m F 1nF 10 m F D Don t insert the capacitors with high voltage into the test jack direct 17 B If the tested signal is too strong you should use the external attenuation so as not...

Страница 12: ...NPN B B E E E PNP E C C Cx KM 6050 POWER LIGHT HOLD Auto Power off 200 2K 20K 200K 2M 20M 200M 200m 2 V 20 200 1000 1000 200 20 V 2 2n 20n 200n 2m 200m 2m 20m 200m 20 20 200m 20m 2m A hFE 20kHz A W F...

Страница 13: ...tion 2 Insert the black test lead into COM socket and the red one into VW Hz jack and connect the test lead to the two ends of the circuit to be tested Remark You must cut off the power before you che...

Страница 14: ...test leads from the input terminals Remove the back cover screws and open the back cover Replace the fuse fuses with new fuse of the same type and rating 0 2A 250V 6 Remove the battery and put it in a...

Страница 15: ...ntees that the product has been inspected and tested in accordance with the published specifications The instrument has been calibrated by using equipment which has already been calibrated to standard...

Страница 16: ...ed dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a greater or different warranty on behalf of KUSAM MECO KUSAM MECO s warranty...

Отзывы: