01
This series of instruments is designed to comply with IEC1010
(International Electro-technical Commission promulgated safety
standards), before use, please read the safety precautions.
1. When measuring the voltage, please input the limit voltage of
DC 1000V or AC 750V rms.
2. The voltage below 36V is safe voltage. When measuring above
36V DC & 25V AC voltage, check whether test pen is reliable
contact or right connected or good insulation properly, whether
insulation is good & so on, in order to avoid electric shock.
3. When Change function & range, test pen should leave the test
point;
4. Select the correct function & range, guard against accidental
operation, the series of instruments although there is full-range
protection, but for safety reasons, you still pay more attention.
5. When measuring current, do not input batteries more than 10A.
6. Safety symbol description, “ ” Exist dangerous voltage,
“ ” Ground, “ ” Double insulation, “ ” Operator must refer
to the instruction manual, “ ” Low voltage symbol.
+
-
I.
Overview :
The 6000 counts is a pocket-sized 3-5/6 bit automatic
digital instrument. Is a stable performance, high precision, high
reliability clear readings, and overload protection. With AAA 1.5V
battery-driven. The instrument uses a large screen LCD display,
boost power supply, even in the 2.3V low battery edge, it can
guarantee the backlight high brightness, the table is easy to carry,
is a vast number of users extremely like the instrument, the back-
light can be bright can be automatically turned off after 15seconds.
This series of instruments can be used to measure the DC Voltage
and AC Voltage DC Current & AC Current, Resistance, Capacitan
ce
diode, Continuity Test, Square-wave output, Frequency measurement
& True RMS measurement & other parameters. Is a ideal tool for
the laboratory, factory, radio enthusiasts & families.
I. SAFETY :
02
FEATURES :
í
Backlight Display
í
Pulse Output
í
Non-Contact Voltage
Measurement (NCV)
í
Sensing :
True RMS
í
Display :
3-5/6 digits 6000 counts liquid crystal LCD display
í
Maximum Display :
5999 counts
í
Sampling Time :
about 3 times / second
í
Operating Temperature :
0°C to 40°C, Relative Humidity <80%
í
Measurement :
Double integral A/D conversion.
í
Overrange Display :
‘OL’
í
Automatic Polarity display.
í
Auto Power Off :
about 15 minutes when no signal.
í
Low Battery Indication :
Below 2.3V
í
Power Supply :
1.5V AAA x 2 battery.
í
Dimension :
Approx.142(L)mm x 70(W)mm x 32(H)mm
í
Weight :
Approx. 205gm (including battery).
í
Accessories :
User Manual, Test leads & Battery.
í
Flash Light
í
Data Hold
í
MAX / MIN & Rel Zero
GENERAL SPECIFICATIONS
●
SAFETY :
Complies with the safety requirements IEC1010 CAT III 600V.