2. Set the range switch to
 “         ” grade, trigger the 
“SELECT” key, select the
 diode measurement, and 
connect the test leads to
the diode was not tested. 
The reading is an 
approximation of forward
voltage drop of the diode.
For silicon PN junction,  
500niV~800niV confirmed

W

W

as normal;if the measured diode open

NOTE : 
Do  not  input  “         ” voltage  symbol, so as  not to damage the 
instrument.

3.Trigger “ SELECT” key to select the buzzer measurement  and
 connect  the test  leads  to  two points of the circuit pending test.
 If the built-in buzzer sounds and the on-off alarm  indicator is on,
 the resistance  between the two points is below(50 20)Q.

circuit or reverse polarity, then display“0L”;

W

CAPACITANCE

±(3.5%rdg + 20dgts)

Range

Accuracy

Resolution

±(5.0%rdg + 3dgts)

10     pF

100   pF

1       nF

10     nF

100   nF

11    

m

F

10    mF

60    nF

600  nF

6      

m

F

60

    m

F

600

  m

F

30   mF

6     mF

15

NOTE : 
1.When measuring low resistance, the table will bring the internal
resistance, in  order to  obtain accurate  readings, you  can firstly 
record  the short-circuit  value of the table  pen, by  testing value 
minus the short-circuit value.
2.When measuring the on-line  resistance, pls make  sure that all 
the circuits  under test must be turned off and a ll capacitors  fully 
discharged in order to ensure the measured value accurately. 
3. Do  not  enter  the voltage  in  the  resistance range,  which  is 
absolutely prohibited, although the instrument in the gear  on  the 
gear on the voltage protection.

Warning: For safety, disable the input voltage  value in  this range! 
1. Insert  the  black test  lead  into the “COM” socket while the red 
meter pen into the “V/

Ω

/Hz” jack; ( note the polarity of the red test

pen is “+”); 

DIODE  & CONTINUITY TEST

Diode forward 
voltage drop

Positive DC Current of about 

1mA, open circuit voltage of 

about 3V.

Range

Test condition

Display Value

Overload Protection : 550V DC or AC peak.

W

The buzzer buzzes
for a long time, & the 
test resistance is less
than (50 ± 20)

W

.

Open circuit voltage is 

about 3V press “SELECT” to

switch between two functions.

Содержание KM 60-T

Страница 1: ...s Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insu...

Страница 2: ...TRMS DIGITAL MULTIMETER MODEL KM 60 T TABLE OF CONTENTS TITLE PAGE NO I Safety II Electrical Specifications III Troubleshooting IV Instrument Layout V Test Certificate VI Warranty 01 02 03 19 23 24...

Страница 3: ...battery driven The instrument uses a large screen LCD display boost power supply even in the 2 3V low battery edge it can guarantee the backlight high brightness the table is easy to carry is a vast n...

Страница 4: ...s Accuracy Resolution Input Impedance 10MW Overload Protection 6V range is 550V DC or AC peak The rest is 1000V DC or 750V AC Peak Maximum input voltage 750V AC RMS or 1000V DC The specific operation...

Страница 5: ...it 3 When measuring high voltage circuit pay special attention to avoid electric shock 4 After completing all measuring operations disconnect the test leads from the circuit under test 06 50 00 D A SE...

Страница 6: ...00mA 250V Speed Glass Fuse DC CURRENT mA 600 mA 6000 mA 0 1 mA 1 mA 1 2 rdg 10dgts Range Accuracy Resolution 08 The specific operation is as follows 1 Insert the black test lead into the COM socket In...

Страница 7: ...n the range switch to the corresponding DC AC mA gear trigger SELECT to select AC m A and then put the meter into the circuit under test The measured current value and the current polarity of the red...

Страница 8: ...0 1 mA 1 mA 1 2 rdg 10dgts Range Accuracy Resolution 12 highest range then according to the display value to the corresponding file such as the screen display 0L that has exceeded the range needed to...

Страница 9: ...rst turn off the power then disconnect the test leads the measured circuit connection Especially to high current measurement 6 It is forbidden to input more than 36V DC 25V AC Voltage between the curr...

Страница 10: ...0 nF 6 mF 60 mF 600 mF 30 mF 6 mF 15 NOTE 1 When measuring low resistance the table will bring the internal resistance in order to obtain accurate readings you can firstly record the short circuit val...

Страница 11: ...e 3 Please test the capacitor capacity before the capacitor should be fully disharged to prevent damage to the fuse and instrumentation 4 Unit IF 1000mF 1mF 1000 F 1uF 1000nf 1nF 1000p 18 Overload Pro...

Страница 12: ...ELECT HOLD MAX MIN REL RANGE FUSED FUSED CAT III 600V 10secMAX 10A MAX 600mA 750V DC 1000V DC 10A COM VWHzmA mA out AUTO POWER OFF TRUE RMS OFF V V NCV W Hz A mA mA out 1 2 3 4 5 6 7 8 9 20 The operat...

Страница 13: ...mA out AUTO POWER OFF TRUE RMS OFF V V NCV W Hz A mA mA out NCV MEASUREMENT 22 If your instrument does not work the following method can help you solve the general problem if the fault still can not b...

Страница 14: ...OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE KUSAM MECO SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INC...

Отзывы: