background image

®

®

17

 

1.Insert the black meter pen 

into the “COM”socket while the

 red meter pen into the “V/

Ω

/Hz”

 jack; 

2. Rotate the dial to the “     ” 

position, trigger the “SELECT”

key and select the capacitance 

profile for automatic measurement.

3. Then connect the test leads 

across the measured capacitance.

NOTE : 

1. When  measuring  the  capacitance  with  10nF range, 

there  maybe  residual  reading  on  the  screen  display 

value.  which is  the  distributed  capacitance of  the  test 

pen. For an accurate  reading, which  can  be  subtracted 

after measurement.

Overload Protection :

 550V DC or AC peak

4.700

 m

F

SELECT

HOLD

MAX/MIN

REL

RANGE

FUSED

FUSED

CAT III 600V

10secMAX

10A

MAX

600mA

750V DC

1000V DC

10A

COM

V

W

HzmA

m

A

out

AUTO POWER OFF

TRUE RMS

OFF

V

V

~

NCV

W

Hz

%

A

mA

~

~

~

m

A

out

!

W

4.7

 m

F

25V

W

2.When large capacitance stalls is measuring serious or

breakdown capacitor, it will show some unstable values; 

it  is  normal that  be  measuring  large  capacitors, the 

reading takes a few seconds to stabilize.

3.Please test the capacitor, capacity before the capacitor

should be fully disharged to prevent damage to the fuse 

and instrumentation.

4.

Unit: IF=1000mF 1mF=1000..F 1uF=1000nf 1nF=1000p

18

Overload Protection :

  550V DC or AC peak (less than 10 seconds)

Input Voltage Range :

 1V rms

FREQUENCY

10       Hz

100     Hz

1       kHz

10     kHz

100   kHz

0.01   Hz

0.1     Hz

1        Hz

10      Hz

100    Hz

±(0.1%rdg + 3dgts)

Range

Accuracy

Resolution

1     MHz

1      kHz

10   MHz

10    kHz

1. Insert the test leads or shielded cables

    into  the “COM”  and  “V/

Ω

/Hz”  jacks; 

2. Turn  the  range  switch  to “Hz”  and 

    connect  the  test  leads  or  cables to 

    the signal source or  load under  test.

NOTE : 

1. When the input exceeds 10Vrms, it can

be  read,  but  it  may  be out of tolerance.

2. In the noise environment, it  is better to 

use shielded cables when measuring small

signals.

3.  When measuring high voltage circuits, 

special attention must be paid to avoid electric shocks;

4. Do  not  input  more  than  250V DC or AC peak voltage to avoid damage to 

the instrument. 

6000

Hz

SELECT

HOLD

MAX/MIN

REL

RANGE

FUSED

FUSED

CAT III 600V

10secMAX

10A

MAX

600mA

750V DC

1000V DC

10A

COM

V

W

HzmA

m

A

out

AUTO POWER OFF

TRUE RMS

OFF

V

V

~

NCV

W

Hz

%

A

mA

~

~

~

m

A

out

!

60Hz

v

~

X

y

Содержание KM 60-T

Страница 1: ...s Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproof Pen Testers Solar Power Meter EMF Detector Wood Paper Grain Moisture Meter Transistorised Electronic Analog Digital Insu...

Страница 2: ...TRMS DIGITAL MULTIMETER MODEL KM 60 T TABLE OF CONTENTS TITLE PAGE NO I Safety II Electrical Specifications III Troubleshooting IV Instrument Layout V Test Certificate VI Warranty 01 02 03 19 23 24...

Страница 3: ...battery driven The instrument uses a large screen LCD display boost power supply even in the 2 3V low battery edge it can guarantee the backlight high brightness the table is easy to carry is a vast n...

Страница 4: ...s Accuracy Resolution Input Impedance 10MW Overload Protection 6V range is 550V DC or AC peak The rest is 1000V DC or 750V AC Peak Maximum input voltage 750V AC RMS or 1000V DC The specific operation...

Страница 5: ...it 3 When measuring high voltage circuit pay special attention to avoid electric shock 4 After completing all measuring operations disconnect the test leads from the circuit under test 06 50 00 D A SE...

Страница 6: ...00mA 250V Speed Glass Fuse DC CURRENT mA 600 mA 6000 mA 0 1 mA 1 mA 1 2 rdg 10dgts Range Accuracy Resolution 08 The specific operation is as follows 1 Insert the black test lead into the COM socket In...

Страница 7: ...n the range switch to the corresponding DC AC mA gear trigger SELECT to select AC m A and then put the meter into the circuit under test The measured current value and the current polarity of the red...

Страница 8: ...0 1 mA 1 mA 1 2 rdg 10dgts Range Accuracy Resolution 12 highest range then according to the display value to the corresponding file such as the screen display 0L that has exceeded the range needed to...

Страница 9: ...rst turn off the power then disconnect the test leads the measured circuit connection Especially to high current measurement 6 It is forbidden to input more than 36V DC 25V AC Voltage between the curr...

Страница 10: ...0 nF 6 mF 60 mF 600 mF 30 mF 6 mF 15 NOTE 1 When measuring low resistance the table will bring the internal resistance in order to obtain accurate readings you can firstly record the short circuit val...

Страница 11: ...e 3 Please test the capacitor capacity before the capacitor should be fully disharged to prevent damage to the fuse and instrumentation 4 Unit IF 1000mF 1mF 1000 F 1uF 1000nf 1nF 1000p 18 Overload Pro...

Страница 12: ...ELECT HOLD MAX MIN REL RANGE FUSED FUSED CAT III 600V 10secMAX 10A MAX 600mA 750V DC 1000V DC 10A COM VWHzmA mA out AUTO POWER OFF TRUE RMS OFF V V NCV W Hz A mA mA out 1 2 3 4 5 6 7 8 9 20 The operat...

Страница 13: ...mA out AUTO POWER OFF TRUE RMS OFF V V NCV W Hz A mA mA out NCV MEASUREMENT 22 If your instrument does not work the following method can help you solve the general problem if the fault still can not b...

Страница 14: ...OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE KUSAM MECO SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INC...

Отзывы: