Kusam-meco KM 078 Скачать руководство пользователя страница 16

®

®

22

MUMBAI

TEST CERTIFICATE

TRMS DIGITAL CLAMPMETER

This Test Certificate warrantees that the product has been 

inspected  and  tested  in  accordance  with  the  published 

specifications.

The  instrument  has  been  calibrated  by  using  equipment 

which has already been calibrated to standards traceable 

to national standards.

MODEL NO. ________________

KM 078

SERIAL NO. ___________

DATE: ___________

ISO 9001

REGISTERED

QC

PASS

KUSAM-MECO

23

WARRANTY

Each “KUSAM-MECO” product is warranted to be free from defects in 
material and workmanship under normal use & service.  The warranty 
period is one year (12 months) and begins from the date of despatch of 
goods.   In case any defect occurs in functioning of the instrument, 
under proper use, within the warranty period, the same will be rectified 
by us free of charges, provided the to and fro freight charges are borne 
by you.
This warranty extends only to the original buyer or end-user customer 
of a “KUSAM-MECO” authorized dealer.
This warranty does not apply for damaged Ic’s, fuses, burnt PCB's, 
disposable batteries, carrying case, test leads, or to any product which 
in “KUSAM-MECO’s” opinion, has been misused, altered, neglected, 
contaminated  or  damaged  by  accident  or  abnormal  conditions  of 
operation or handling.
“KUSAM-MECO” authorized dealer shall extend this warranty on new 
and unused products to end-user customers only but have no authority 
to extend a greater or different warranty on behalf of “KUSAM-MECO”.
“KUSAM-MECO’s”  warranty  obligation  is  limited,  at  option,  free  of 
charge repair, or replacement of a defective product which is returned 
to a “KUSAM-MECO” authorized service center within the warranty 
period.
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY 
AND  IS  IN  LIEU  OF  ALL  OTHER  WARRANTIES,  EXPRESS  OR 
IMPLIED,  INCLUDING  BUT  NOT  LIMITED  TO  ANY  IMPLIED 
WARRANTY  OF  MERCHANTABILITY  OR  FITNESS  FOR  A 
PARTICULAR PURPOSE.  “KUSAM-MECO” SHALL NOT BE LIABLE 
F O R   A N Y   S P E C I A L ,   I N D I R E C T,   I N C I D E N TA L   O R  
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF 
DATA, ARISING FROM ANY CAUSE WHATSOEVER.
All transaction are subject to Mumbai Jurisdiction.

Содержание KM 078

Страница 1: ...with DC Zero mode on DCA DC ACA ranges Temperature Coefficient Nominal 0 15 x o o o o o specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Power Supply Standard 1 5V AAA Size Battery X...

Страница 2: ...M AMPTIP CLAMP ON DC CURRENT 1 2 3 Accuracy Resolution 2 0 rdg 5dgts 0 01 A 60 00 A 1 Induced error from adjacent current carrying conductor 0 01A A 2 Specified with DC Zero mode applied to offset the...

Страница 3: ...00 0 433 0 416 3 8 2 000 0 331 0 243 26 5 2 000 0 242 0 130 46 2 One limitation to making true RMS measurements is crest factor and you should consider crest factor when making AC measurements Crest f...

Страница 4: ...Thermo Anemometer Thermo Hygrometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Ca...

Страница 5: ...s for equipment intended to be supplied from the building wiring It applies both to plug connected equipment and to PERMANENTLY CONNECTED EQUIPMENT OVERVOLTAGE CATEGORY III CAT III is for equipment in...

Страница 6: ...I 600V or better This Clamp on meter is designed to apply around or remove from uninsulated hazardous live conductors But still individual protective equipment must be used if hazardous live parts in...

Страница 7: ...cessories Test leads set User Manual Soft carrying case V SPECIFICATIONS 05 Safety Double insulation per UL IEC EN61010 1 Ed 3 IEC EN61010 2 033 Ed 1 CAN CSA C22 2 No 61010 1 Ed 3 IEC EN61010 2 032 Ed...

Страница 8: ...dg 5dgts 10 mA 50Hz 60Hz Diode Tester Test Current 0 3mA typically Open Circuit Voltage 3 5VDC typically 2 000 V 1 5 rdg 5dgts 1 Accuracy Resolution Range 1 mV 07 1 Induced error from adjacent current...

Страница 9: ...ep tones proportional to the field strength Detection Frequency 50 60Hz Detection Antenna Inside the top side of the stationary jaw Probe Contact EF Detection For more precise indication of live wires...

Страница 10: ...DCA polarity at where best current accuracy is specified 11 VII OPERATION WARNING Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to de...

Страница 11: ...I 600V CAT IV 300V PEAK RMS REC SELECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V EF Live Ground 13 CAUTION WARNING for Non Invasive Clamp on Curr...

Страница 12: ...HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V 6008 Hz SELECT 1 HZ Non Invasive Regular Current Functions ACA DCA DC ACA Hz Input is made via the clam...

Страница 13: ...ECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V 0602 W V AUTO PEAK RMS REC SELECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A...

Страница 14: ...meter consecutive measurement with the main display displaying reading as the reference value LCD turns on Press the button for one second or more to toggle Relative Zero mode HOLD 80ms PEAK RMS mode...

Страница 15: ...e like open fuses to protect the user and the instrument Most measuring functions through this terminal might then be open circuit Such components should only be replaced by qualified technician Refer...

Страница 16: ...horized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered ne...

Отзывы: