In  other  words,  the  meter  will  intelligently  avoid  entering  the  APO 
mode  when  it  is  under  normal  measurements.  To  wake  up  the 
meter  from  APO,  press  the 

SELECT

  button  momentarily  and

release, or turn the rotary switch OFF and then back on. Always turn
the rotary switch to the OFF position when the meter is not in use.

V. MAINTENANCE :

To  avoid  electrical  shock,  disconnect  the  meter  from  any  circuit, 
remove  the test leads from the input jacks and turn OFF the meter
before opening the case. Do not operate with open case.

WARNING :

If the instrument fails to operate, check batteries and test leads etc.,
and  replace  as  necessary.  Double  check  operating  procedure  as
described in this manual.

Trouble Shooting :

If the instrument voltage-resistance input terminal has subjected to
high voltage transient (caused by lightning or switching surge to the 
system under test) by accident or abnormal conditions of  operation, 
the protective impedance components in series might be blown off
(become  high  impedance)  like  open  fuses  to  protect  the  user  and 
the  instrument.  Most  measuring  functions  through  this  terminal 
might  then  be  open  circuit.  Such  components  should  only  be 
replaced  by  qualified  technician.  Refer  to  the  WARRANTY  section 
for obtaining warranty or repairing service.

Intelligent Auto-Power-Off (APO) :

The  Auto-Power-Off  (APO)  mode turn the meter off automatically to
extend  battery  life  after  approximately  32  minutes  of  no  specified 
activities, where applicable :
1. Rotary switch or push button operations.
2. Significant measuring readings of above 8.5% of ranges.
3. Non-OL readings for Resistance, Continuity or Diode function.
4. Non-zero readings for Hz function.
5. Significant movement indication as in Phase Rotation functions.

21

Periodically wipe the case with a damp cloth and mild detergent; do 
not  use  abrasives  or  solvents.  If  the  meter  is  not  to  be  used  for 
periods of longer than 30 days, remove the batteries and store them
separately.

Cleaning and Storage :

Battery replacement :

The meter uses standard 1.5V AAA Size (IEC R03) battery X 2.
Loosen  the  2  captive  screws  from  the  battery  cover  case.  Lift  the
battery  cover  case.  Replace  the batteries.  Replace battery cover 
case. Re-fasten the screws.

Содержание KM 078

Страница 1: ...with DC Zero mode on DCA DC ACA ranges Temperature Coefficient Nominal 0 15 x o o o o o specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Power Supply Standard 1 5V AAA Size Battery X...

Страница 2: ...M AMPTIP CLAMP ON DC CURRENT 1 2 3 Accuracy Resolution 2 0 rdg 5dgts 0 01 A 60 00 A 1 Induced error from adjacent current carrying conductor 0 01A A 2 Specified with DC Zero mode applied to offset the...

Страница 3: ...00 0 433 0 416 3 8 2 000 0 331 0 243 26 5 2 000 0 242 0 130 46 2 One limitation to making true RMS measurements is crest factor and you should consider crest factor when making AC measurements Crest f...

Страница 4: ...Thermo Anemometer Thermo Hygrometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Ca...

Страница 5: ...s for equipment intended to be supplied from the building wiring It applies both to plug connected equipment and to PERMANENTLY CONNECTED EQUIPMENT OVERVOLTAGE CATEGORY III CAT III is for equipment in...

Страница 6: ...I 600V or better This Clamp on meter is designed to apply around or remove from uninsulated hazardous live conductors But still individual protective equipment must be used if hazardous live parts in...

Страница 7: ...cessories Test leads set User Manual Soft carrying case V SPECIFICATIONS 05 Safety Double insulation per UL IEC EN61010 1 Ed 3 IEC EN61010 2 033 Ed 1 CAN CSA C22 2 No 61010 1 Ed 3 IEC EN61010 2 032 Ed...

Страница 8: ...dg 5dgts 10 mA 50Hz 60Hz Diode Tester Test Current 0 3mA typically Open Circuit Voltage 3 5VDC typically 2 000 V 1 5 rdg 5dgts 1 Accuracy Resolution Range 1 mV 07 1 Induced error from adjacent current...

Страница 9: ...ep tones proportional to the field strength Detection Frequency 50 60Hz Detection Antenna Inside the top side of the stationary jaw Probe Contact EF Detection For more precise indication of live wires...

Страница 10: ...DCA polarity at where best current accuracy is specified 11 VII OPERATION WARNING Before and after hazardous voltage measurements test the voltage function on a known source such as line voltage to de...

Страница 11: ...I 600V CAT IV 300V PEAK RMS REC SELECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V EF Live Ground 13 CAUTION WARNING for Non Invasive Clamp on Curr...

Страница 12: ...HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V 6008 Hz SELECT 1 HZ Non Invasive Regular Current Functions ACA DCA DC ACA Hz Input is made via the clam...

Страница 13: ...ECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A Hz COM CAT III 600V CAT IV 300V 0602 W V AUTO PEAK RMS REC SELECT HOLD ZERO OFF MAX 600A 600V CAT III 300V CAT IV EF W A Hz Hz V A...

Страница 14: ...meter consecutive measurement with the main display displaying reading as the reference value LCD turns on Press the button for one second or more to toggle Relative Zero mode HOLD 80ms PEAK RMS mode...

Страница 15: ...e like open fuses to protect the user and the instrument Most measuring functions through this terminal might then be open circuit Such components should only be replaced by qualified technician Refer...

Страница 16: ...horized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered ne...

Отзывы: