background image

22

THIS  WARRANTY  IS  BUYER’S  SOLE  AND 

EXCLUSIVE  REMEDY AND  IS  IN  LIEU  OF ALL 

OTHER WARRANTIES, EXPRESS OR IMPLIED, 

INCLUDING  BUT  NOT  LIMITED  TO  ANY 

IMPLIED  WARRANTY  OF  MERCHANTABILITY 

OR  FITNESS  FOR  A  PARTICULAR  PURPOSE.   

“KUSAM-MECO”  SHALL  NOT  BE  LIABLE  FOR 

ANY  SPECIAL,  INDIRECT,  INCIDENTAL  OR 

CONSEQUENTIAL  DAMAGES  OR  LOSSES, 

INCLUDING  LOSS  OF  DATA,  ARISING  FROM 

ANY CAUSE WHATSOEVER.

All transaction are subject to Mumbai Jurisdiction.

G 17,Bharat Industrial Estate, T. J. Road, 

Sewree (W), Mumbai - 400 015. INDIA.

Sales Direct :

 (022) 24156638

Tel. :

 (022) 24124540, 24181649.

Fax :

 (022) 24149659

Email :

 [email protected]

Website :

 www.kusamelectrical.com, 

                 www.kusam-meco.co.in

Содержание 9999

Страница 1: ...re current the same way as they measure voltage Remember you measure voltage across a circuit and current through a circuit When you use the current input your clamp meter becomes a low impedance circ...

Страница 2: ...n Qty 1 English Operating Manual 1 piece 2 Test Lead 1 pair 3 K Type Thermocouple 1 piece 4 Thermocouple Adaptor 1 piece In the event you find any Part missing or damaged please contact your dealer im...

Страница 3: ...er F out side the o o o range of 18 to 28 C 65 F to 82 F Indoor use Altitude up to 2000m Safety Conformance All input are protected to EN61010 1 600V CAT III Pollution degree II EMC instrument unspeci...

Страница 4: ...9999 W 0 1 1 Accuracy CAPACITANCE Range Resolution 0 to 999 9m F 0 1 m F Accuracy 5 rdg 10dgts Overload Protection 600V DC AC rms NOTE Supplied Thermocouple is suitable for o measurement upto 250 C f...

Страница 5: ...pose a shock hazard 5 When using the probes keep your fingers behind the finger guards on the probes 6 Measuring voltage which exceeds the limits of the Clampmeter may damage the meter and expose the...

Страница 6: ...cy Capacitance Temperature measurements and Continuity Diode Checks 8 FUNCTIONAL BUTTONS POWER ON THE METER Turn on the meter To select power on option Turn the rotaryswitch from zero position to any...

Страница 7: ...s 2 Press the trigger to open transformer jaws and clamp on to one conductor only and turn on the motor 3 Read the INRUSH current directly from display Press and hold down the INRUSH button for more t...

Страница 8: ...AX 999 9 VA m F W Hz 100 AUTO ZERO HOLD AC 0 25 50 75 AC P HOLD MAX MIN 11 m f m f Unit of Capacitance 12 A AC CURRENT MEASUREMENT 1 Set the range rotary switch to A 2 Press the trigger to open transf...

Страница 9: ...III 600V DATA PEAK 600V MAX O Hz V A V O F W O C H B DC CURRENT MEASUREMENT Red Black AUTO ZERO MIN MAX HOLDH AC 9999 VA m F k9Hz 9999 TRMS 0 25 50 75 100 VW COM INRUSH MAX MIN ZERO Hz APO 2S O Cx Hz...

Страница 10: ...V DATA PEAK 600V MAX O Hz V A V O F W O C H 16 1 Set the range rotary to position The is displayed 2 Turn off power to the circuit under test External voltage across the components causes invalid read...

Страница 11: ...re Measurements K type Red Black AUTO ZERO MIN MAX HOLDH AC 9999 VA m F k9Hz 9999 TRMS 0 25 50 75 100 VW COM INRUSH MAX MIN ZERO Hz APO 2S O Cx Hz A CAT III 600V DATA PEAK 600V MAX O Hz V A V O F W O...

Страница 12: ...the warranty period the same will be rectified by us free of charges provided the to and fro freight charges are borne by you This warranty extends only to the original buyer or end user customer of...

Страница 13: ...MECO SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE WHATSOEVER All transaction are subject to Mumbai Jurisdic...

Отзывы: