The Clampmeter Structure

1) TRANSFORMER JAWS :

Pick up the AC current flowing through the 
conductor.

2) TRIGGER :

Press the lever to open the transformer jaws. When
the lever is released, the jaws will close again.

3) FUNCTION SELECTOR :

To Select 

ACV, ACA, DCV, DCA, RESISTANCE, 

      FREQUENCY, CAPACITANCE, TEMP., 
      DIODE & CONTINUITY.

4)  LCD DISPLAY :

A  4 digit display (maximum reading 9999)
indicates measured values, and features symbols 
indicating function, Data - Hold, Peak Hold, Max   
Hold, Low Battery, Continuity, Diode along  with             
40 Segment Analog Bar Graph.

5) INPUT JACKS (V

W

+

, and COM- ) :

Test leads are inserted into these jacks for
Voltage, Resistance, Frequency, Capacitance, 

     Temperature measurements  and Continuity & 
     Diode Checks.

8

FUNCTIONAL BUTTONS

POWER  ON  THE  METER

Turn on the meter : To select power on option.   Turn 

the  rotaryswitch  from  "zero"  position 

to  any  switch 

position. 

Turn off the meter: Turn the range rotaryswitch into 

"zero " position  to  turn off  the meter.

AUTOMATIC  POWER  OFF

The  display  blanks  and  the  meter  enters 

the APO  mode  if  you  have  not  changed  the  rotary 

switch position or pressed a button for 10 minutes.

In APO mode the "AUTO" is displayed.  While in APO 

mode, change the rotary switch to turn the meter on.

INRUSH  current  &  APO  Function 

Button :

In  "INRUSH"  current  function,  the  meter 

takes  a  large  number  of  samples  precisely  at  the 

beginning of the starting current for a 100-milli second 

period  and  then  digitally  filters  and  processes  the 

samples to calculate the actual staring current.   The 

"INRUSH" function is enabled at the ACA and DCA 

range.

9

Содержание 9999

Страница 1: ...re current the same way as they measure voltage Remember you measure voltage across a circuit and current through a circuit When you use the current input your clamp meter becomes a low impedance circ...

Страница 2: ...n Qty 1 English Operating Manual 1 piece 2 Test Lead 1 pair 3 K Type Thermocouple 1 piece 4 Thermocouple Adaptor 1 piece In the event you find any Part missing or damaged please contact your dealer im...

Страница 3: ...er F out side the o o o range of 18 to 28 C 65 F to 82 F Indoor use Altitude up to 2000m Safety Conformance All input are protected to EN61010 1 600V CAT III Pollution degree II EMC instrument unspeci...

Страница 4: ...9999 W 0 1 1 Accuracy CAPACITANCE Range Resolution 0 to 999 9m F 0 1 m F Accuracy 5 rdg 10dgts Overload Protection 600V DC AC rms NOTE Supplied Thermocouple is suitable for o measurement upto 250 C f...

Страница 5: ...pose a shock hazard 5 When using the probes keep your fingers behind the finger guards on the probes 6 Measuring voltage which exceeds the limits of the Clampmeter may damage the meter and expose the...

Страница 6: ...cy Capacitance Temperature measurements and Continuity Diode Checks 8 FUNCTIONAL BUTTONS POWER ON THE METER Turn on the meter To select power on option Turn the rotaryswitch from zero position to any...

Страница 7: ...s 2 Press the trigger to open transformer jaws and clamp on to one conductor only and turn on the motor 3 Read the INRUSH current directly from display Press and hold down the INRUSH button for more t...

Страница 8: ...AX 999 9 VA m F W Hz 100 AUTO ZERO HOLD AC 0 25 50 75 AC P HOLD MAX MIN 11 m f m f Unit of Capacitance 12 A AC CURRENT MEASUREMENT 1 Set the range rotary switch to A 2 Press the trigger to open transf...

Страница 9: ...III 600V DATA PEAK 600V MAX O Hz V A V O F W O C H B DC CURRENT MEASUREMENT Red Black AUTO ZERO MIN MAX HOLDH AC 9999 VA m F k9Hz 9999 TRMS 0 25 50 75 100 VW COM INRUSH MAX MIN ZERO Hz APO 2S O Cx Hz...

Страница 10: ...V DATA PEAK 600V MAX O Hz V A V O F W O C H 16 1 Set the range rotary to position The is displayed 2 Turn off power to the circuit under test External voltage across the components causes invalid read...

Страница 11: ...re Measurements K type Red Black AUTO ZERO MIN MAX HOLDH AC 9999 VA m F k9Hz 9999 TRMS 0 25 50 75 100 VW COM INRUSH MAX MIN ZERO Hz APO 2S O Cx Hz A CAT III 600V DATA PEAK 600V MAX O Hz V A V O F W O...

Страница 12: ...the warranty period the same will be rectified by us free of charges provided the to and fro freight charges are borne by you This warranty extends only to the original buyer or end user customer of...

Страница 13: ...MECO SHALL NOT BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES INCLUDING LOSS OF DATA ARISING FROM ANY CAUSE WHATSOEVER All transaction are subject to Mumbai Jurisdic...

Отзывы: