Extraction path upwards
At the installation point of the hood there must be an exhaust channel
150 mm in diameter in the room ceiling.
Extraction path to the side
The hood must be connected by an additional exhaust channel to the
exhaust opening (150 mm diameter) in a room wall.
Exhaust with external motor (IKDEM 908.1)
The exhaust air can be extracted upwards or to the side (see above). The
control cable of the external motor should come out of the ceiling at the
installation point of the hood with a free cable length of about 1000 mm.
Marking and drilling holes
Note the following for marking the holes:
The power cable and, where applicable, the control cable of the external
motor are passed through the recesses at the exhaust opening of the
cover into the interior of the chimney.
Install the hood so that the cables are hidden by the chimney panelling.
The hood should hang centrally over the cooking surface so that as
many fumes as possible are extracted directly.
–
Align the drilling template above the cooking surface and mark the holes.
–
Drill holes for the enclosed dowels and insert dowels.
Mounting the inner frame
The length of the inner frame governs the length of the telescopic chimney.
Caution! When the hood is installed, the distance between the
lower edge of the hood and the cooker must be at least 650 mm.
The distance between the lower edge of the inner frame and the
cooker must accordingly be 952 mm.
–
Pass the customer’s power cable and, where applicable, the control cable
of the external motor through the ceiling plate of the inner frame.
–
Screw the inner frame to the
ceiling.
–
Set the length of the inner frame
so that the distance between the
cooking surface and the lower
edge of the inner frame is at least
952 mm.
–
Screw the two parts tight together
again.
Installing the exhaust pipe
–
Cut the exhaust pipe supplied to
the appropriate length and attach
with a clip to the customer’s
exhaust pipe.
–
Let the customer’s power cable
and, where applicable, the control
cable of the external motor hang
down outside the exhaust pipe.
Mounting the upper chimney panelling
–
Push the upper chimney panelling
over the inner frame and screw
on with two screws.
952
mm
IKD 908.1
19