34
Caution!
This appliance has only to be connected to a network 230 V~ 50/60 Hz.
Connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a
medium screwdriver. Place it in the slits and open the cover.
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put a bridge between terminal L1 and L2 and between terminal N1 and N2.
Attach the earth to the terminate “earth”, the neutral N to one of the terminals N1 or N2, the Phase L
to one of the terminals L1 or L2.
Biphase 400V~2P+N
Put a bridge between terminal N1 and N2.
Attach the earth to the terminate “earth”, the neutral N to terminal N1 or N2, the Phase L1 to the
terminals L1 and the Phase L2 to the terminal L2.
Caution! Be careful that the cables are correctly engaged and tightened.
Mains
Connection
Cable diameter
Cable
Protection calibre
230V~ 50/60Hz
1 Phase + N
3 x 2,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
4 x 1.5 mm²
H 05 VV - F
H 05 RR - F
16 A *
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.