background image

18

Service Manual

F

o

r i

n

te

rn

al

 us
e o

n

ly

13.

Circuit diagram

Содержание KD 3700.0

Страница 1: ...Cooker hood IKD 3700 0 ...

Страница 2: ...ce Manual H5 76 03 Responsible U Laarmann KÜPPERSBUSCH HAUSGERÄTE AG E mail uwe laarmann kueppersbusch de Phone 0209 401 732 Kundendienst Fax 0209 401 743 Postfach 100 132 Date 12 10 2007 45801 Gelsenkirchen ...

Страница 3: ...ion 8 6 Buttons and functions 9 6 1 Buttons 9 6 2 Functions 10 7 Procedure for repairs 11 7 1 Changing the halogen lamp 12 7 2 Replacing the entire lamp block 12 8 Accessing the connection box 13 9 Removing the electrical components 14 10 Removing the motor block 15 11 Technical data 16 12 Faults and the cause 17 13 Circuit diagram 18 ...

Страница 4: ...rrent circuit breaker must always be used The earthed conductor resistance must not exceed the resistance specified in the standard It is vital for ensuring the safety of persons and the functioning of the appliance On completion of repairs an inspection must be carried out in accordance with VDE 0701 Association of German Electrical Engineers or in accordance with the corresponding regulations fo...

Страница 5: ...e of simultaneous operation of a hood and a heater requiring ambient air negative pressure in the room in which the heat er and the hood are installed does not exceed 0 04 mbar thus ensuring that the exhaust gases of the heaters will not be re absorbed The room must be fitted with ventilation connections which ensure a constant inflow of fresh air ATTENTION This appliance must be earthed Make sure...

Страница 6: ...6 Service Manual For internal use only 3 Dimensions Extraction mode Recirculation mode Baffle plate Grease filter Charcoal filter ZUB 839 Diverting flange Reduction piece Flange ...

Страница 7: ...plied in the bag of accessories for making holes in the ceiling Lay the drilling tem plate on the ceiling as a vertical extension of the hob and drill the holes Ø 160 mm hole is only used for the extraction model The Ø 40 mm hole is required for leading the mains cables through ...

Страница 8: ... internal use only 5 Screw specification 1 Screws for fastening the panel onto the ceiling 4 8 x 38 mm 2 Screw for fastening the deflector 3 9 x 9 5 mm 3 Screw for fastening the decorative pipe 3 9 x 9 5 mm stainless steel ...

Страница 9: ...lighting Button C Reduce the motor speed to zero The hour metre is set at zero if pressed for 2 sec when the fire alarm has gone off Button D Activate the motor by calling up the last speed set and drive up the speed until the top speed is reached Button E Activate deactivate the sensor AUTOMATIC or MANUAL operation mode The sensor is activated in the automatic operation mode and the letter A will...

Страница 10: ... while the filter alarm is being indicated in order to reset the hour metre Sensitivity of the gas sensor The sensitivity of the gas sensor may be adjusted to suit the personal needs of a user To adjust the sensitivity the appliance must be in the manual operation status i e the letter A is not shown on the display instead the current speed is shown Button E may need to be pressed The degree of se...

Страница 11: ...he odour filters if the hood has been installed in the recirculating air mode Check Before you carry out any repair work make sure that the Check steps to determine minor errors or faults have been carried out Noises or unusual vibrations Check to ensure that the installation screws are tightly fastened Check to ensure that the extraction panel of the edge suction device is properly closed The hoo...

Страница 12: ...power supply before it is cleaned or be fore any maintenance work is carried out Proceed as follows to replace a lamp or lamp mounting 1 Open the cover by levering it off at the corresponding slits 2 Replace with a new lamp of the same type ATTENTION Never touch a new lamp with your bare hands 3 Check the functioning 7 2 Replacing the entire lamp block 1 Disconnect the connection of the lamp block...

Страница 13: ...t is cleaned or before any maintenance work is carried out 1 Remove the connections of the two lamps 2 Press the two clips on the side and take out the lamp block 3 Remove the metal frame after the four screws A have been removed 4 Loosen the two knurled screws B but do not remove them 5 Remove the control element block Fig 4 Fig 5 Fig 6 ...

Страница 14: ...the two clips on the side and take out the lamp block Fig 3 3 Remove the metal frame after the four screws A have been removed Fig 4 4 Loosen the two knurled screws B but do not remove them Fig 5 5 Take out the control element block Fig 6 6 Take off the bottom decorative pipe after the four screws C have been removed Fig 7 and pull it out downwards 7 Take out the top decorative pipe after the two ...

Страница 15: ... been removed Fig 4 4 Loosen the two knurled screws B but do not remove them Fig 5 5 Take out the control element block Fig 6 6 Take off the bottom decorative pipe after the four screws C have been removed Fig 7 and pull it out downwards 7 Pull out the outgoing air tube though the opening at the back Fig 10 8 Remove the four nuts and the four washers and take the motor block E off the bottom struc...

Страница 16: ...170 max Electrical connection 250 W Halogen lighting 2 x 20 W Air rate Level 1 Level 2 Level 3 300 m h 440 m h 645 m h Pressure Level 1 Level 2 Level 3 340 Pa 425 Pa 470 Pa Resistance Level 1 red blue Level 2 red white Level 4 red black 129 6 Ω 108 9 Ω 67 5 Ω Noise Level 1 Level 2 Level 3 39 dB 47 dB 56 dB Exhaust air connection 150 mm ...

Страница 17: ...The light does not work The lamp has burned out Replace with the same mode and reference The hood does not have enough power Check whether the motor velocity selected is sufficient for the quantity of smoke and steam which occurs the kitchen has been sufficiently ventilated in order to enable the air extraction opening to be opened the charcoal filter has been used up air circu lation hood the sen...

Страница 18: ...18 Service Manual For internal use only 13 Circuit diagram ...