H1-58-01-04
7
Only for internal use
1.5
Connection of the honeycomb cooking zone to the
honeycomb control unit and power module
Trip line plugs of the honeycomb cooking zone are plugged into six sockets of the honeycomb control
unit. For this the cables must point to the middle of the honeycomb control unit. Plugs for the power line
in the honeycomb control unit have to be plugged into to the sockets of the power module. For single-
circuit honeycomb cooking zones any socket can be used. For dual-circuit cooking zones, however, one
of the three sockets for dual-circuit cooking zones on the power module have to be used. The
honeycomb control unit is connected via power line to the power module. The power module is
connected to the fixed connection (oven connection socket) with a mains cable.
Only use a H 05 RR-F or H 05 RN-F connection cable with a minimum length of 1.5 m.
1.6
Cover panel for the honeycomb cooking zone in the lower
cupboard
To prevent a contact between the electrical lines and the hot honeycomb cooking zone from below a
cover panel is inserted under the cooking zone in the lower cupboard.
This cover panel may only be removed with tools from the lower cupboard. You can order this cover
panel as an optional accessory at Küppersbusch.
Cover panel for the honeycomb cooking zone in the lower cupboard
honeycomb
honeycomb
power module
cover panel
cooking zone
control unit