16
Service Manual EDG 650.0
For internal use only
6.5
Removing the upper air duct
1.
Remove the upper air duct.
2.
Removing the tangent.
3.
Remove the 2 screws on the tangent and the 6 screws on the flap.
4.
Lift the air duct slightly and release the cable clamp underneath.
6.6
Removing the tangent
1.
Remove the upper air duct.
2.
Disconnect the two electric wires.
6.7
Removing the reed switch card
1.
Unplug the connector.
2.
Wrap a piece of cloth around a
screwdriver. Carefully insert the screwdriver between
the card and the reservoir bracket.
3.
Gently prise out the card, taking care not to damage it.
4.
Repeat these steps with each of the 3 clips until the card is
completely free.
Warning!
If the card is damaged, the reed switches may be affected.
Following removal and reinstallation of the control card, systematically check
that the reed switch is working correctly!
6.8
Removing the water level sensor
1.
Release the mounting clip underneath the water level probe.
2.
Lift and bend the probe in order to remove it from its mounting.
3.
Unplug the connector.
6.9
Removing the water reservoir bracket
1.
Take out the reservoir
2.
Take out the reed switch card.
3.
Unplug the connector.
4.