Service Manual EDG 650.0
15
For internal use only
6.
Maintenance and repair
IMPORTANT:
Before starting any repair or maintenance work, disconnect the appliance from the
mains and connect all earth units.
Make sure you have taken all necessary safety precautions before you begin.
Cut off power to the appliance
first of all by removing the fuse at the main fusebox
and then, once the appliance has been removed from its housing unit, by removing the plug from the
wall socket.
Before removing the cooker from its housing unit
-
remove all cooking utensils
-
take out the reservoir
6.1
Removing the upper air duct
1.
Take off the upper protective cap
2.
Take out the thermoactivator.
3.
Remove the 8 screws on lower air duct.
4.
Pull the upper air duct towards the back of the unit and release from the fascia.
6.2
Removing the thermoactivator
1.
Remove the upper air duct.
2.
Release the two electric wires.
3.
Remove the top cover.
6.3
Removing the flap
1.
Pull back the upper air duct.
2.
Release the flap by sliding it out along the line of the activator.
6.4
Removing the flap seal
1.
Remove the upper air duct.
2.
Remove the 2 screws on the tangent and the 6 screws on the flap.
3.
Withdraw the seal.
Warning: Observe the correct position when refitting and check for a good connection between
the interior and the air duct.