Figure 11: Correct position for combustion chamber shell
Figure 12: Correct positioning of fuel logs
(a) Start immediately: Shut all of the boiler doors when starting the boiler electrically. Now
press the electrical start button on the control panel. The ignition system is then in operation.
Please read the control panel operating instructions at this juncture. During the ignition phase,
the primary fan runs at 100% speed and the secondary fan runs at 20% speed. The fans
stop running when the furnace chamber door is opened! Once the ignition phase has been
completed, the unit switches automatically into normal heating mode.
(b) Programmed Start: The time at which the electrical ignition activates can be programmed
using the control panel. To learn how to do this, please read the control panel operating
instructions. When selecting the ignition time, it should be considered that the boiler must
run for about an hour before it can provide the heating system with its full output. Once
the ignition phase has been completed, the unit switches automatically into normal heating
mode.
4. Start manually: Light the fire over the turbo-disk using newspaper or a barbecue lighter and very
dry small pieces of kindling wood. Gradually add more small pieces. Let the fire burn with the
feeder hatch closed and the ash door open and then add more small wood. If, after 10 to 15 mins.
there are enough glowing embers in the combustion chamber, carefully distribute the embers and
then lay on some small logs. Now the heating-up hatch and the „START“ button on the control
panel can be activated. Soon after this a wood flue flame will form in the feeding chamber. After