Plug the ignition coil into the ignition duct and screw it tightly into position using the union nut.
Reconnect the cable plug (with the green/yellow earthing cable connected to the centre slot!).
Ensure that the cable points downwards and does not interfere with the fan damper.
The plenum chamber door can then be closed again. When closing the plenum chamber, ensure that the
seal is correctly seated everywhere. A leaking plenum chamber negatively affects the operation of the
unit!
5.3
Quarterly cleaning
5.3.1
Smoke ducts
In addition to the maintenance described above, the ventilation on the boiler must also be serviced ev-
ery quarter year . With time dust from the air will cause the blades of the ventilators to block so that
insufficient air is transported.
Also the rear ascending flue must be cleaned. To do so, remove the rear casing cover and open the
cleaning hatch. The flue is now open and can be cleaned with the special brush provided. After cleaning,
close the cleaning hatch and replace the casing cover. The ash formed is collected in the bend behind the
ash try and must be removed, e.g. with a vacuum cleaner.
Please note: The flue gas sensor is located in the upward gas passage. When cleaning the corresponding
gas passage, work with particular care in order to avoid damaging the sensor.
Remember that a clean boiler has a higher degree of efficiency and will burn more reliably and effectively.
It helps to reduce pollution of the environment and also saves fuel and therefore also your money.
The hinges on the feeding hatch and the ash flap can be adjusted to optimize the hatch sealings. Release
the counter-nut on the eye-bolt pull our the hinge bolts and pull these hatch carefully towards you or
hang it out altogether. Now adjust the eye-bolt and replace the hatch-door. Grease all the movable parts
with a drop of oil so that they can be easily moved in future.
5.3.2
Fans
Caution: Always pull out the mains plus before undertaking any work on the fans!
The fans of the biturbo unit are 24 volt fans. Should it be necessary to disconnect the fan cables, it must
be ensured that the correct coloured cables are allocated to the right units when re-connecting the cables.
The FD fans are easily soiled by the dust in the air in the vicinity of the boiler. The dust is deposited on
the blades of the ventilator so that it cannot transport sufficient air into the system. It is best to use an old
toothbrush to clean the blades. Remove the red casing cover. The fans are now exposed. You can then
clean the blades with a small brush (e.g. an old toothbrush). In doing so, at intervals you should remove
the dust with a vacuum cleaner. If the ventilators are heavily soiled , it may be necessary to dismantle
the ventilation fans. To do this, release the fixing screws on the ventilator flange and remove the fan. The
screws on the back of the fan can be unscrewed and the whole unit removed from its casing. The blades
are now accessible from all sides and can be cleaned e.g. with compressed air. After cleaning the fan can
be re-assembled by following the above instructions in reverse order. Caution: When first starting-up
again after cleaning, there may be a strong accumulation of dust. We recommend you to clean the
ventilator three times per year.