KUNBUS-COM EtherCAT
114 / 135
2.11.2.2 Xid Switch Settings
If you want to assign the Explicit Device ID via the SSC, enter [2] +
[Return] in the "Explicit ID Settings" menu. The SSC is now selected
as the current configuration source. By entering [9] + [Return] the
displayed menu window opens.
Here, you can select the required settings:
– 2x BCD: Data are interpreted as two-digit BCD values.
– 2x 8 Bit:: Data are interpreted as 2x 8-Bit-binary value.
--------------------------------------------------
KUNBUS-IC - EtherCAT Xid Switch Settings
--------------------------------------------------
Actual: Station Alias 2x 8 Bit
1 - Station Alias 2x BCD
2 - Station Alias 2x 8 Bit
--------------------------------------------------
>
2.12 Set Arbitrary Register
In this menu you have the option,to make adjustments to the
writeable registers that do not have their own menu item.
First enter the register number:
--------------------------------------------------
KUNBUS-
COM
– Set Arbitray Register
--------------------------------------------------
Register Number:
If the register number does not exist or is write-protected, you will
receive a corresponding error message.
--------------------------------------------------
KUNBUS-
COM
– Set Arbitray Register
--------------------------------------------------
Register Number: 0x5001 <<Register doesn‘t exist or no write access
.Register Number:
If the register number is valid, the dialog first shows you the set value
in decimal, hexadecimal and binary notation.
--------------------------------------------------
KUNBUS-
COM
– Set Arbitray Register
--------------------------------------------------
Register Number: 0x0013
Current Value : 1 0x0001 0000_0000_0000_0001b
Enter New Value:
Now specify a new value for the register and press [Return] to
confirm your entry.
CDI