SSC Mode
In this menu you have the option, to configure the shift register chain.
You can choose between the following modes using the Direction Pin
(b2):
– SSC SSR Master Mode (Default value, Direction Pin not set)
– SSC SPI Slave Mode (Direction Pin set)
2.3 Select SSC SSR Master
Mode
Prerequisite:
The Direction Pin (b2) is not set. As a result, the
master mode is active.
In this menu you have the following options:
– SSC SSR Master Mode, disabled: With this option, you switch off the
SSC.
– SSC SSR Master Mode, auto detect shift registers: With this option, the
number of input/output shift registers and the bitrate is determined
automatically.
– SSC SSR Master Mode, configured shift registers: With this option, you
can define the number of input/output shift registers and the bitrate
yourself.
– Enter [3] + [Enter] to select this mode as the configuration source.
– With the option [9] you open the configuration menu.
--------------------------------------------------
KUNBUS-
COM
- Select SSC SSR Master Mode
--------------------------------------------------
Mode: SSC SSR Master Mode, configured shift registers
1 - SSC SSR Master Mode, disabled
2 - SSC SSR Master Mode, auto detect shift registers
3 - SSC SSR Master Mode, configured shift registers
--------------------------------------------------
>
2.3.3 SSC SSR Master Mode,
configure shift registers
Prerequisite:
In menu "2.3 - Select SSC SSR Master Mode" you
have selected the configuration source "SSC SSR Master Mode,
configure shift registers".
In this menu you have the following options:
– Number of input shift registers
– Number of output shift registers
– Bitrate
--------------------------------------------------
KUNBUS-
COM
- SSC SSR Master Mode, configure shift registers
--------------------------------------------------
1 - Number of overall Input Registers: 0
2 - Number of overall Output Registers: 0
3 - Configured Bitrate: 300 kBit/s
--------------------------------------------------
>