2-S12
GL6000, GL7000, GL9000, GL11000, WSM
GENERATOR
Safety Switch Continuity (for Terminal Type)
1. When the safety switch (1) is turned
ON
and
OFF
, measure the
resistance between the terminals of it each time.
2. (a) when the measurement are the above table value.
The safety switch (1) is normal.
(b) when the measurement are out of the above table value.
THe safety switch (1) is failure, then please exchange it.
W10210220
Lamp Timer (for Glow Plug)
1. Remove the lamp timer from inside of the panel.
2. Connect the battery (4), lamp timer (1) and bulb (2) as shown in
the figure.
3. The bulb (2) light up when contacting the lead wire 1 (3) with
positive terminal of the battery (4) and goes off approximately 6
seconds late, the lamp relay is proper.
W1022263
Resistance
ON
Infinity
OFF
0
(1) Safety Switch
A : ON
(1) Lamp Timer for Glow Plug
(2) Bulb
(3) Lead Wire 1
(4) Battery (12 V)
KiSC issued 05, 2015 A