2-S11
GL6000, GL7000, GL9000, GL11000, WSM
GENERATOR
Main Switch Continuity
1) Main Switch Key at OFF Position
1. Set the main switch
OFF
position.
2. Measure the resistance with an ohmmeter across the
30
terminal
and the
AC
terminal,
30
terminal and
50
terminal,
30
terminal and
19
terminal.
3. If infinity is not indicated, the contacts of the main switch are
faulty.
2) Main Switch Key at ON Position
1. Set the main switch
ON
position.
2. Measure the resistance with an ohmmeter across the
30
terminal
and the
AC
terminal.
3. If 0 ohm is not indicated, the
30
–
AC
contact of the main switch
are faulty.
3) Main Switch Key at GL Position
1. Set and hold the main switch key at the
GL
position.
2. Measure the resistance with an ohmmeter across the
30
terminal
and the
19
terminal, and measure the resistance across the
30
terminal and the
AC
terminal.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
4) Main Switch Key at START Position
1. Set and hold the main switch key at the
START
position.
2. Measure the resistance with an ohmmeter across the
30
terminal
and the
19
terminal, across the
30
terminal and the
50
terminal,
and across the
30
terminal and the
AC
terminal.
3. If 0 ohm is not indicated, these contacts of the main switch are
faulty.
W10136580
Safety Switch (for Terminal Type)
1. Open the control panel (1).
2. Disconnect the terminals and remove the safety switch (2).
W1020471
Resistance
30
terminal –
AC
terminal
Infinity
30
terminal –
50
terminal
30
terminal –
19
terminal
Resistance
30
terminal –
AC
terminal
0
Resistance
30
terminal –
19
terminal
0
30
terminal –
AC
terminal
Resistance
30
terminal –
19
terminal
0
30
terminal –
50
terminal
30
terminal –
AC
terminal
(1)
19
Terminal
(2)
AC
Terminal
(3)
50
Terminal
(4)
30
Terminal
(1) Control Panel
(2) Safety Switch
KiSC issued 05, 2015 A