Dok. Nr. R60744_Index 1a
Page 20 / 27
6.3. Serial Settings
Parameter
Min
Max Default
Unit Number:
Unit numbers between 11 … 99 can be assigned to the devices
(default setting = 11). Unit numbers with “0“ are forbidden
because these are used for group‐ or bulk‐addressing.
11
99
11
Serial Baud Rate:
0
9 600
Baud
1
4 800
Baud
2
2 400
Baud
3
1 200
Baud
4
600
Baud
5
19 200 Baud
6
38 400 Baud
7
56 000 Baud
8
57 200 Baud
9
76 800 Baud
10
115 200 Baud
0
10
0
Serial Format:
0 7 data bit
parity even
1 stop bit
1 7 data bit
parity even
2 stop bit
2 7 data bit
parity odd
1 stop bit
3 7 data bit
parity odd
2 stop bit
4 7 data bit
parity ‐‐‐
1 stop bit
5 7 data bit
parity ‐‐‐
2 stop bit
6 8 data bit
parity even
1 stop bit
7 8 data bit
parity odd
1 stop bit
8 8 data bit
parity ‐‐‐
1 stop bit
9 8 data bit
parity ‐‐‐
2 stop bit
0
9
0
Serial Init
This parameter determines the baud rate for the transmission
of the initialization values to the operator surface OS6.0
respectively to the SMCB.1 programming‐ and display unit.
0:
The initialization values will be transmitted with 9600 baud.
After initialization the unit works with the user settings again.
1:
The initialization values will be transmitted with the user
defined baud rate. After initialization the unit works with the
user settings again.
With settings higher than 9600 baud, the duration of the
initialization procedure can be shortened.
0
1
0