KTR Kupplungstechnik
GmbH
D-48407 Rheine
NVT-E
Operating-/Assembly Instructions
KTR-N
Sheet:
Edition:
42611 EN
15 of 27
1
Please note protection
mark ISO 16016.
Drawn:
11.10.12 Pz/Wy
Replaced for:
---
Verified:
19.11.12 Pz
Replaced by:
4 Operation
4.7 Switching Outputs
All switching outputs are set in the same way. Therefore, the number of the switching output is marked x. Select
the switching output to be set via the menu of the corresponding measurement size (
or
).
Table 6: Assignment of switching outputs (factory-provided)
Switching output
Assignment with
2 switching outputs
Assignment with
4 switching outputs
1
Charging level
Charging level
2 Temperature
Charging
level
3
Temperature
4
Temperature
A T T E N T I O N !
The assignment of the switching outputs as well as further basic settings referring to all
switching outputs can be modified in the menu Basic settings extended functions.
The submenu Extended functions allows to execute further settings for each switching
output affecting, for example, the switching behaviour of the output. Testing the output is
possible here, too.
4.7.1 Definition of Switching Characteristics
The switching characteristics for the output are defined in the following menu:
The following menu items are available:
Hysteresis function
Hysteresis function
make contact
Hysteresis function
break contact
Function of make contact or break contact setting
the output signal when exceeding the switching
point defined. If the reset point is fallen below, the
output signal is deleted.
Make contact
means here that the PNP switching
output is closed if the measured value is above the
switching point
x and is opened if the reset point
x is fallen below.
Break contact
means here that the PNP switching
output is open if the measured value is above the
switching point
x and is closed if the reset point
x is fallen below.