background image

KTR Kupplungstechnik 

GmbH 

D-48407 Rheine 

NVT-E 

Operating-/Assembly Instructions 

KTR-N 
Sheet: 
Edition:

 

42611 EN 
8 of 27 

 

Please note protection 

mark ISO 16016. 

Drawn: 

11.10.12 Pz/Wy 

Replaced for: 

--- 

Verified: 

19.11.12 Pz 

Replaced by: 

 

 

4 Operation 

 

4.3 Key Functions 

 
To select a menu item and set the values please proceed as follows:  

  Open the main menu via the key 

  Select the submenu via the keys 

 and 

 and open the submenu via the key 

  If applicable, select the next submenu via the keys 

 and 

 and open it using the key 

  Select the requested menu item via the keys 

 and 

 and open the parameter list via the key 

  Set the value using the keys 

 and 

 and accept via the key 

The amended settings are saved and the device returns to the submenu.  

  Exit the submenu by selecting menu item EXIT and press key 

 to accept. 

The device returns to the superordinate menu or measured value display, respectively.  

 
 
 

4.4 Key Lock Active 

 
If the key lock is activated, retrieving the menu via key 

 shows the display 

 

instead of the main menu. The active digit is indicated by a dot. 
 

  Enter the code via the keys 

 and 

 and press the key 

 to accept. 

The active digit shifts to the right by one place. Having entered the 3

rd

 digit the main menu is opened. 

 

 

A T T E N T I O N !

 

Having entered an incorrect code, the device returns to measured value display. If you have 
lost the password, enter the master code 287 to return to the menu.

 

 
To unlock the key lock, reset the password to the input 000 in the menu item  

  in the sub-menu 

Basic 

Settings Extended Functions

  

 
 
 

4.5 Summary of Menu 

 
The menu structure is based on the VDMA standard 24574 and following.  
The menu has a hierarchy structure. The highest menu level includes input of the main menu, e. g.  

,   

,  

,  

,   . Each main menu comprises further submenu items. 

 
The menu items may vary depending on the configuration of the device. Your device may not provide all menu 
items described below. You can retrieve the configuration by pressing the key 

 in the display mode. A 4-digit 

code is displayed, e. g.: 
 

 

Meaning of the 4-digit code tsav: 

t: Type 
 
s:  number of switching outputs 
a:  number of analogue outputs 
v:  mounting of device

t = temperature 

measurement 

o  =  level and temperature measurement 
2 or 4 
0 or 2 
i  =  standard mounting (installation of 
  tank) 

 
 
 
 
 

Содержание NVT-E 2S Series

Страница 1: ...407 Rheine NVT E Operating Assembly Instructions KTR N Sheet Edition 42611 EN 1 of 27 1 Please note protection mark ISO 16016 Drawn 11 10 12 Pz Wy Replaced for Verified 19 11 12 Pz Replaced by NVT E O...

Страница 2: ...General Hints to Danger 2 4 Proper Use 3 Assembly 3 1 Starting General 4 Operation 4 1 Switching On 4 2 LED Status Display 4 3 Key Functions 4 4 Key Lock Active 4 5 Summary of Menu 4 6 Amendment of B...

Страница 3: ...per Limit 4 8 2 Assignment of Lower Limit 4 8 3 Defining the Type of Signal 4 8 4 Testing the Analogue Output 4 9 Diagnostics 4 9 1 Opening the Journal 4 9 2 Maximum Minimum Charging Level 4 9 3 Maxim...

Страница 4: ...and control unit Display 4 digit 7 segment LED display Operation over 3 keys Memory Min and max value memory Current consumption with starting approx 100 mA for 100 ms Current consumption during oper...

Страница 5: ...ing safety instructions All operations on and with the NVT E have to be performed taking into account safety first Please make sure to disengage the power pack before you perform your work on the NVT...

Страница 6: ...The electric connection may be performed by trained technical staff only Connection The mains voltage is connected to connector S6 or M12 respectively Nominal voltage of devices is 24 V DC Please ref...

Страница 7: ...s 4 3 Key Functions Operation is performed via the keys underneath the display Table 3 Key functions Key Operation mode Function Measured value display Switching the displayed units example Within the...

Страница 8: ...ve digit is indicated by a dot Enter the code via the keys and and press the key to accept The active digit shifts to the right by one place Having entered the 3rd digit the main menu is opened A T T...

Страница 9: ...formed first since they affect displays and settings in the different menus General settings are for example the units used and the classification of the switching outputs for measurement of charging...

Страница 10: ...ing menu items are available Per cent cm Inch Litre Gallons None Please note If no unit is selected the measured values are scaled to a 4 digit display The measured values are not automatically conver...

Страница 11: ...hifted from the menu charging level to the menu temperature The procedure for amending the settings does not change A T T E N T I O N With a re assignment of the switching outputs all corresponding se...

Страница 12: ...The active digit shifts to the right by one place Finally accept the code by pressing the key The device returns to the submenu Please note Enter 000 to deactivate the key lock 4 6 6 Scaling of Charg...

Страница 13: ...g 4 6 8 Minimum Displayed Value of Charging Level The displayed value lower limit of the measurement range for the minimum charging level is defined here Setting range 999 9999 Assignment of the maxim...

Страница 14: ...itching characteristics of switching output x Unit for charging level temperature Maximum minimum charging level x Assignment of switching output x towards charging level or temperature monitoring Upd...

Страница 15: ...the menu Basic settings extended functions The submenu Extended functions allows to execute further settings for each switching output affecting for example the switching behaviour of the output Testi...

Страница 16: ...s left Make contact means here that the PNP switching output is closed if the measured value is within the window limits Otherwise the switching output is open Break contact means here that the PNP sw...

Страница 17: ...on window was assigned to the switching output OUT 1 is displayed The value set corresponds to the upper window limit If the function frequency output was assigned to the switching output OUT 1 is dis...

Страница 18: ...o enable the switching output to respond Please note If the function window was assigned to the switching output OUT x the value set corresponds to the delay for set point detecting when the measureme...

Страница 19: ...n in the table below Table 7 Numbering of LED Switching output x Assignment with 2 switching outputs Assignment with 4 switching outputs 1 LED 1 yellow LED 1 yellow 2 LED 2 red LED 2 red 3 LED 3 yello...

Страница 20: ...PNP switching output 4 is closed Error LED4 and LED3 on only LED4 on C Temperature dropping to 75 C PNP switching output 4 is opened OK LED3 on LED3 off D Temperature dropping to 65 C PNP switching ou...

Страница 21: ...the measurement range 10 If the range selected is too small the analogue output value may have steps 4 8 2 Assignment of Lower Limit The assignment is defined as to which charging level is necessary t...

Страница 22: ...n of the test please make absolutely sure to set the function to normal operation 4 9 Diagnostics The device is in a position to record the incidents for a switching output A result is defined as an i...

Страница 23: ...ated in the following way Example Latest incident took place x hours ago h days ago d Incidents 2 to 5 took place x hours days ago Latest incident took place x hours days ago Delete not yet recorded o...

Страница 24: ...ue of charging level reached x hours days ago delete function Key Key Key Key Key delete Menu order Max value time Min value time delete Accepting the display via the key deletes the journal and retur...

Страница 25: ...he minimum and maximum charging level can be set Here the period in seconds is set during which the signal must remain continuous before the charging level is recorded Delay storing Min Max Delay MM d...

Страница 26: ...ulting herefrom 6 Disposal In respect of environmental protection we would ask you to dispose of the products on termination of their service life in accordance with the effective legal regulations an...

Страница 27: ...failures are saved in the device until it is switched off Breakdowns Causes Elimination no display No supply voltage 1 inspect cable and replace if necessary Error indication in the display toggles b...

Отзывы: