KTMED OXYPALM Скачать руководство пользователя страница 1

 

 

 

 

Operator’s Manual

 

OXYPALM 

(Ver. 1.04) 

Palm Type Pulse Oximeter 
 
 
 

 

 

 

 

 

012

Содержание OXYPALM

Страница 1: ...Operator s Manual OXYPALM Ver 1 04 Palm Type Pulse Oximeter 012 ...

Страница 2: ... Sensor 12 3 2 Turn On Off 12 Section 4 Setup 4 1 Sensor 4 1 1 Recognizing Sensor 13 4 1 2 Recognizing whether a finger slips out of Sensor 13 4 2 System sound volume set 14 4 3 Alarm set 4 3 1 Alarm sound volume set 14 4 3 2 Alarm interval time set 15 4 4 Alarm limit set 4 4 1 SpO2 low alarm limit set 15 4 4 2 Pulse rate high alarm limit set 15 4 4 3 Pulse rate low alarm limit set 16 4 5 Time set...

Страница 3: ...shipment The KTMED s obligation under this warranty is limited to repairing or replacing any part which upon KTMED s examination proves to be defective KTMED s obligation or liability under this warranty does not include anything that results from the improper use or application of the product or any substitution involved with its parts or accessories that are approved by KTMED Inc or if any repai...

Страница 4: ...use big problems that can t be covered by us Return Procedure In the event that it becomes necessary to return a unit to KTMED Inc the following procedures should be followed 1 Contact KTMED Inc Service Department at 82 2 2108 7890 Please provide the model number serial number and a brief description of the reason for the product s return 2 The customer is responsible for any freight charges when ...

Страница 5: ... at the same time it may breakdown Caution The purpose of a Caution is to inform the user of an operating procedure practice etc which if not followed could result in minor personal injuries or possible damage to the equipment You should use sensors supplied by KTMED Inc If any other device is used it may damage to the unit Note A NOTE is used to inform the user of ways to install operate and main...

Страница 6: ...anufactured to meet the accuracy specifications for pulse oximeter Using other manufacturers sensors may cause improper pulse oximeter performance And do not use a damaged sensor z Remove the manicure and any dirt from the patient s nails z Follow local governing ordinances and recycling instructions regarding disposal or recycling of device components including batteries z Inaccurate measurements...

Страница 7: ...ational Electro technical Commission IEC has established a set of symbols for medical electrical equipment regarding connections or warnings of potential hazards The classification and symbols are shown below Symbol Description Attention consult ACCOMPANYING DOCUMENTS Date of manufacture Serial Number Type BF APPLIED PART Direct Current Low Battery Data Transmission If you are uncertain about the ...

Страница 8: ... with class B for noise emission Level B for noise immunity per standard of EN 60601 1 2 Electromagnetic Compatibility Requirements Warning Caution There is a risk of explosion if the battery is replaced with an incorrect type Do not dispose of the used batteries in fire put in the batteries backwards mix new and used batteries and use other types of batteries together Or there may be an explosion...

Страница 9: ... the purpose that once the sensor is connected to a patient it works on its own and that doctors and medical staff can analyze the result with ease OXYPALM stores 72hours of data and transfers the data to PC There is PC software to analyze the data 1 2 Applications OXYPALM is indicated for use in measuring and displaying functional oxygen saturation and pulse rate for neonate pediatric and adult O...

Страница 10: ...step Indicator General Condition Maximum consumption power 20VA Weight 250g main body batteries 120g main body Operating temperature 0 to 50 Storage temperature 20 60 Humidity 10 95 non condensing Battery specification Sanyo 4pcs AA internal Battery running life 20hours non stop working Measuring range 0 100 Accuracy 1 90 100 2 80 89 3 65 79 Unspecified below 64 Low alarm limit 85 99 1 step Yellow...

Страница 11: ...lay It shows the pulse rate per minute Indicator of alarm silence It indicates the alarm silence If you press button green LED blinks Indicator It is on when the batteries are low Menu Button It is used to adjust system volume alarm interval time alarm range and time Power Button It is used to turn on off the power in the main body Indicator of pulse rate magnitude It indicates the pulse rate of a...

Страница 12: ...Manual 10 2 1 2 Side Panel Figure 4 Sensor socket It is used to connect the sensor Battery case cover It is the case for batteries to be built in 2 1 3 Rear Panel Figure 5 Sensor socket It is used to connect the sensor Battery case cover It is the case for batteries to be built in ...

Страница 13: ...PALM can be powered by 4 AA size Sanyo batteries With the 4 batteries it works non stop for 20 hours Change the batteries as shown in Figure 7 Be sure to insert the batteries in the correct position as indicated by the polarity markings in side the battery compartment If batteries are positioned incorrectly the device might be breakdown Figure 7 Installing batteries in the OXYPALM ...

Страница 14: ...d be used 3 2 Turn on off Turn on the OXYPALM by pressing and holding the on off button on the front of the unit for 2seconds Turn off the unit by pressing and holding the on off button on the front of the unit for 2seconds FND is indicated as shown Figure 8 and the power goes off Figure 8 Initial display When turn on the device all indicators are turned on for 3seconds as shown Figure 9 Please ch...

Страница 15: ...sor When the power is on but the sensor is unconnected a message as shown Figure 10 comes up Figure 10 4 1 2 Recognize whether a finger slips out of Sensor If the sensor is connected while a finger slips out of it windows of SpO2 and Pulse rate show 0 a pulse rate searching lamp is on Figure 11 ...

Страница 16: ... OXYPLAM s menus are not round type In other words menus navigate from first menu to SEn OPn measurement mode on forward direction Then it moves to measurement mode If you want to call back previous menu press about 2 seconds And you can set each menu again 4 3 Alarm set 4 3 1 Alarm sound volume set Press button about 2 seconds and use button to display as Figure 13 If you want to adjust alarm sou...

Страница 17: ...m 4 4 1 SpO2 low alarm limit set Press button about 2 seconds and use button to display as Figure 15 If you want to adjust SpO2 low alarm limit press You can set the SpO2 low alarm limit from 85 to 99 1 1step Figure 15 4 4 2 Pulse rate high alarm limit set Press button about 2 seconds and use button to display as Figure 16 If you want to adjust Pulse rate high alarm limit press You can set the pul...

Страница 18: ... low alarm limit press You can set the pulse rate low alarm limit from 30 to 250 5bpm 1step Figure 17 4 5 Time set Press and hold the menu button while pressing and releasing the on off button Display shows as shown in Figure 18 Sequence of time set is year month day hour and minute Change the value with menu button press on off button when the desired value appears to advance to the next sequenti...

Страница 19: ...SECTION 4 Setup KTMED Inc Model OXYPALM Operator s Manual 17 Figure 18 Year Figure 19 Month Figure 20 Day ...

Страница 20: ...SECTION 4 Setup KTMED Inc Model OXYPALM Operator s Manual 18 Figure 21 Time Figure 22 Minute Figure 23 Second ...

Страница 21: ...asically stored date is not cleared Delete all stored date by press menu button when display shows yes After the date is deleted clearly OXYPALM will then exit setup mode and is ready to begin normal operation 4 6 Data output Connect PC and OXYPALM with the supplied PC communication cable Order a transmission on PC display will show as shown Figure 24 Figure 25 Data Transmission Stored data is tra...

Страница 22: ...cks When you ask its authorized representative for service the manufacturer s label serial number date of original purchasing date will be required We recommend you have to check regular calibrations at least every 2 years In this case please contact KTMED or its authorized representative for service If the defects in materials or workmanship are found within two year from the date of original pur...

Страница 23: ...obin absorbs more red light and allows more infrared light to pass through Red light is in the 600 750 nm wavelength light band Infrared light is in the 850 1000 nm wavelength light band Pulse oximeter uses a light emitter with red and infrared LEDs that shines through a reasonably translucent site with good blood flow Typical adult pediatric sites are the finger toe pinna top or lobe of the ear I...

Страница 24: ...r Case Battery for OXYPALM KTMED Inc Model OXYPALM Operator s Manual 22 1 Assembly Procedure of Rubber Case Push the unit into the rubber case as shown in the below figure Pull the end of rubber cover over the unit as shown in the below figure ...

Страница 25: ...ual 23 2 Replacing Batteries Push the battery door as shown in the below figure Remove four batteries as shown in the below figure First Insert two batteries in both ends of the battery case as shown in the below figure Second Insert batteries that the middle of the battery case as shown in the below figure ...

Страница 26: ...APPENDIX B Replacement Procedure of Rubber Case Battery for OXYPALM KTMED Inc Model OXYPLUS Operator s Manual 24 Push the Battery door and close it as shown in the below figure ...

Страница 27: ...purchasing date is marked will be required So please keep this card carefully PRODUCT Palm Type Pulse Oximeter Warranty Period MODEL OXYPALM S N 2 years DATE DESCRIPTION OF REPAIR REMARK PURCHASING DATE Name Tel CUSTOMER INFORMATION Address Name Tel DISTRIBUTED BY Address ...