MAINTENANCE WORK ON CHASSIS AND ENGINE
62
400240-10
–
Connect the battery charger to the battery. Switch on the battery charger.
Battery charger (58429074000)
You can also use the battery charger to test rest potential and start potential of the
battery, and to test the generator. With this device, you cannot overcharge the bat-
tery.
Info
Never remove the lid
.
Charge the battery according to the instructions
on the battery casing.
–
Switch off the charger after charging. Disconnect the battery.
Specification
The charge current, charge voltage and charge time must not be exceeded.
Charge the battery regularly when the
motorcycle is not in use.
3 months
–
Mount the seat (
8.74
Removing the main fuse
–
Switch off all power-consuming components and switch off the engine.
–
Remove the seat (
600108-10
–
Remove the protection cover
.
–
Remove the main fuse.
8.75
Fitting the main fuse
Warning
Fire hazard
The electrical system can be overloaded by the use of incorrect fuses.
–
Use only fuses with the prescribed amperage. Never by-pass or repair fuses.
600108-11
–
Check parts for damage and wear. Replace damaged or worn parts.
Info
A reserve fuse
is located in the starter relay.
Replace a burned-out main fuse
only by an equivalent fuse.
–
Insert the main fuse.
Fuse (58011109130)
Info
If the new fuse burns out, contact an authorized KTM workshop.
–
Replace the protection cover.
–