-14-
Management Objects
Console Telnet Web SNMP
Port state - enable/disable
Yes Yes Yes Yes
Port status - link, speed
Yes Yes Yes Yes
Port static counters
Yes Yes Yes Yes
Device Mac address information
Yes Yes Yes Yes
System firmware version information
Yes Yes Yes
-
System hardware version information Yes Yes Yes
-
System default configuration version Yes Yes Yes
-
G1, G2 module information
Yes Yes Yes Yes
F23, F24 module information
Yes Yes Yes Yes
Cooling Fan1 Fan2 status
Yes Yes Yes Yes
LACP status
Yes Yes Yes
-
IGMP snooping information
- -
Yes
-
Stacking configuration
- -
Yes
-
Stacking switches monitoring
- -
Yes
-
RFC 1213 MIB-2 objects
- -
-
Yes
RFC 1493 Bridge MIB
- -
-
Yes
RFC 1271 RMON MIB (group 1,2,3,9) - -
-
Yes
1.4.2 SNMP Traps
Trap Events
The table below lists the events the device will generate SNMP traps.
Generic: RFC1157 generic, Specific: EnterpriseSpecific
Type
Trap
Event
Generic
Cold Start
Device bootup
Generic
Authentication
SNMP authentication failure
Generic
Port link change Port link down
Generic
Port link change Port link recovery
Specific
Fan1 failure
Cooling Fan1 failure warning
Specific
Fan1 failure
Cooling Fan1 failure recovery
Specific
Fan2 failure
Cooling Fan2 failure warning
Specific
Fan2 failure
Cooling Fan2 failure recovery
Содержание KS-2260
Страница 117: ... 117 5 5 5 2 Aggregator Information The following pages illustrate three examples No active group configured ...
Страница 118: ... 118 Two Static Trunking groups are configured ...
Страница 119: ... 119 One LACP trunk group is formed Trunking information between Actor and Partner are shown ...
Страница 131: ... 131 5 5 8 Spanning Tree This page shows an example of STP Root Bridge information of the switch ...
Страница 132: ... 132 This page shows an example of STP port status Refer to Chapter 1 for the description of Spanning Tree Protocol ...
Страница 149: ... 149 6 Click Update Firmware in following download complete message to confirm the update 7 Reboot the system ...