-30-
2. Installation and Management
2.1 Panel Description
2.2 AC Power Supply
One AC power cord which meets the specification of your country of
origin was supplied with the switch unit. Before installing AC power cord
to the switch, make sure the AC power switch is in OFF position and the
AC power to the power cord is turned off. The switch supports wide
range of AC power input specifications as follows:
Power Rating :
100 ~ 240VAC, 50/60Hz, 50W
Voltage Range :
90 ~ 260VAC
Frequency :
47 ~ 440 Hz
Inrush Current :
24A@230V
Minimal Consumption : 17W
Maximal Consumption : 26W