-33-
The following 100FX modules are supported by F23 and F24 slots:
Part Number Connector
Cable
Distance
2260-FMT
Duplex ST
MMF*
2 km
2260-FMC
Duplex SC
M M F
2 km
2260-FJM
MT-RJ
M M F
2 km
2260-FVM
VF-45
M M F
2 km
2260-FSA2
Duplex SC
SMF*
20 km
2260-FSL2
Duplex SC
SMF
2-30 km
Note:
* MMF - Multimode Fiber cable 50/125, 62.5/125
* SMF - Single Mode Fiber cable 8.7/125, 9/125, 10/125
Specifications
IEEE 802.3u 100BASE-FX compliant, Fixed 100Mbps, Fixed Full duplex
Optical Specifications
Part Number Wavelength
Output Power
Input Optical Power
2260-FMT
1310nm
-19 ~ -14dBm
-31dBm min. -14dBm max.
2260-FMC
1310nm
-19 ~ -14dBm
-31dBm min. -14dBm max.
2260-FJM
1310nm
-20 ~ -14dBm
-31dBm min. -14dBm max.
2260-FVM
1310nm
-20.5 ~ -15dBm
-33dBm typ. sensitivity
2260-FSA2
1310nm
-18 ~ -7dBm
-32dBm max. sensitivity
2260-FSL2
1310nm
-15 ~ -8dBm
-34dBm max. sensitivity
Installation steps:
1. Turn the power to the switch off.
2. Set JP1.
3. Insert the 100FX modules and screw the modules securely.
4. Turn the power to the switch on.
Содержание KS-2260
Страница 117: ... 117 5 5 5 2 Aggregator Information The following pages illustrate three examples No active group configured ...
Страница 118: ... 118 Two Static Trunking groups are configured ...
Страница 119: ... 119 One LACP trunk group is formed Trunking information between Actor and Partner are shown ...
Страница 131: ... 131 5 5 8 Spanning Tree This page shows an example of STP Root Bridge information of the switch ...
Страница 132: ... 132 This page shows an example of STP port status Refer to Chapter 1 for the description of Spanning Tree Protocol ...
Страница 149: ... 149 6 Click Update Firmware in following download complete message to confirm the update 7 Reboot the system ...