10
Operating Manual ECOTROC ATCN 15-110
3.2 Danger zones
Risk from pressure-bearing
parts
Risk of slipping due to spilt active carbon on
the floor
•
Never operate the oil vapour adsorber outside of the load limits shown on the vessel
plate.
•
Never carry out work as long as the oil vapour adsorber is under pressure.
•
Do not modify the structure of the oil vapour adsorber or change its function.
•
Only use the oil vapour adsorber for its intended purpose.
•
Do not climb onto the device.
•
Do not carry out welding work on pressure-bearing parts.
•
Wear respiratory protection and eye protection when changing the active carbon.
•
Risk of slipping due to spilt active carbon.
•
Always check that the indicator pipe is secure before you open the needle valve and
remember to wear eye protection.
•
Never operate the device if there is apparent damage.
•
Avoid sparks and naked flames in the vicinity of the active carbon as it is combustible.
•
Never lift the oil vapour adsorber by the equipment parts, only use the lifting lugs.
Active carbon
The active carbon used does not fall into the hazardous substances group and is therefore not subject to label-
ling requirements. Nevertheless, please observe all common safety measures with regard to using chemicals.
Please also note that the material accumulates contaminants, in particular oil. This can cause additional dan-
gers.
Should you require further information, contact the manufacturer to obtain a copy of the safety datasheet.