KSH International CO., LTD.
34
Factory Default Setting
If by chance, you forget the setup password, or have incorrect settings making
the converter inoperable, there are two ways to reset the setting and the
following procedures can be used to reset all settings to factory default:
A:
1.
you can turn off the power and then use any point tip to push “Reset”
button and hold it to turn on the power at the same time for 5 seconds.
The password will be reset to the factory default
.
B:
1.
Turn off the power of the converter.
2.
Use a pin or any point tip to push the screw driver or any conductor to
short DTR and CTS (pin 4 and pin 8 in DB9) of RS232 connector.
3.
Turn on the power of the converter and wait 5 seconds and remove
screwed driver or conductor.