KSH International CO., LTD.
26
□
□
□
DHCP client
DHCP client mode could be enabled/disabled status. If DHCP is enabled, there
should be a DHCP server on the network. If DHCP is disabled, [IP address],
[Subnet mask], and Gateway address] should be manually assigned.
□
□
□
Socket port of HTTP setup
The socket port used to conduct the browser setup. Normally, HTTP protocol
use TCP port “80” for communication. If the field is changed to “81”, the port
“80” will be reserved for user's own Web.
To enter the browser setup page, “http://x.x.x.x:81” should be typed for socket
port “81” and “http://x.x.x.x” for socket port “80”, where “x.x.x.x” is the
converter’s IP address..
□
□
□
Destination IP address
The server IP address and socket port would be connected in TCP Client and
UDP Client mode for a certain serial port.
□
□
□
Destination socket port
The server socket port would be connected in TCP Client and UDP Client mode
for a certain serial port.
□
□
□
Packet mode of serial input
Packet mode could be in enabled/disabled mode. If packet mode is enabled, the
data input from UART will be deferred until the input buffer is full, or the
converter detects a 10-character packet gap and no more character arrived. The
block waiting time is extended to avoid the splitting of the complete packet.
□
□
□
Packet mode inter-packet timeout
Packet gap detection time constant, ranging from 10 to 1000 ms.