9 Related Documents
90 of 98
UPA / UPA S
3400.86/17-EN
9.2.2 UMA 200, UMA-S 200 mating dimensions
CAUTION
Incorrect pump connection
Damage to the pump set!
▷
The pump shaft must rest on the motor shaft.
Observe the following dimensions:
1.
Axial tolerance: 1.2 ± 0.6 mm
2.
Dimension to be set: 101.5 ± 0.1 mm
Ø
1
8
9
67
45°
4
1
Ø1
52
,5
Ø1
27
h7
Ø1
7,5
Ø
1
8
9
Ø
3
7
,9
-0
,1
Ø
1
2
7
h
8
4,5
101,5
±0,1
6
67
-0,1
Ø7,5
+0,1
Fig. 52:
UMA 200, UMA-S 200 mating dimensions in [mm]
9.2.3 UMA 250, UMA-S 250 mating dimensions
CAUTION
Incorrect pump connection
Damage to the pump set!
▷
The pump shaft must rest on the motor shaft.
Observe the following dimensions:
1.
Axial tolerance: 1.0
+0.7
/
-0.6
mm
2.
Dimension to be set: 101.5 ± 0.1 mm
4
8
81
Ø1
90
,5
Ø1
27
h7
45°
Ø2
2
Ø
4
2
,8
h
7
Ø
1
2
7
h
7
Ø
2
3
2
5
20
101,5
±0,1
Fig. 53:
UMA 250, UMA-S 250 mating dimensions in [mm]