5 Installation at Site
22 of 60
Multi Eco
Connecting the suction line
ü
Use a special suction line of at least the same nominal diameter as the pump's
suction nozzle.
ü
A sand filter is connected to the suction line.
(The suction strainer must have a mesh size of more than 2 mm. For fluids
containing sand (max. 50 g/m³) the suction strainer must have a mesh size of less