5 Installation at Site
20 of 60
Multi Eco
5 Installation at Site
5.1 Safety regulations
DANGER
Unsuitable electrical installation
Danger to life!
▷
Make sure the electrical installation meets the VDE 0100 and IEC 60364
installation rules (i.e. sockets with earthing terminals).
▷
Make sure the electric mains is equipped with a residual current device of
maximum 30 mA.
▷
If in doubt, contact a specialist electrical company.
DANGER
Use in an outdoor area
Danger of death from electric shock!
▷
The pump set must be installed at a distance of at least 3 metres from the fluid
reservoir.
▷
Do not expose electrical connections to any moisture.
▷
Any extension cord must match the quality of the supplied cable.
▷
Verify that all sealing elements at the pump's terminal box are properly fitted.
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷
Always have the electrical connections installed by a trained and qualified
electrician.
▷
Observe regulations IEC 60364.
DANGER
Using damaged power cables
Danger of death from electric shock!
▷
Never connect any damaged power cables.
▷
Visually inspect the power cable before connecting it.
▷
Replace the power cable if it is damaged.
DANGER
Damaged terminal box
Danger of death from electric shock!
▷
Never operate a pump with a damaged terminal box.
WARNING
Excessive operating pressure
Fluid spurting out and parts flying off as a result of components bursting!
▷
If the pump is to be installed in pressurised piping, fit a pressure reducer
upstream of the pump.