5 Installation at Site
29 of 60
Multi Eco
CAUTION
Drive and pump running in the wrong direction of rotation
Damage to the pump!
▷
Observe the arrow indicating the direction of rotation on the pump's name
plate.
▷
Check the direction of rotation. If required, check the electrical connection and
correct the direction of rotation.
1.
Start the motor and stop it again immediately to determine the motor's
direction of rotation.
2.
Check the direction of rotation.
The motor's direction of rotation must match the arrow indicating the direction
of rotation on the pump's name plate.
3.
If the motor runs in the wrong direction of rotation, check the electrical
connection of the motor and the control system, if applicable.