9 Related Documents
53 of 64
MK
9.1.2 MK, MKA - grease-lubricated
920.11
550.11
400.11
710.01
210
712.01
545
920.02
902.02
303.02
561.02
230
102
502
303.01
68-3
400.12
902.01
920.01
520
801
901.01
903.11
411.11
321
500.01
561.01
550.01
902.12
920.12
635
731.30
731.31
710.30
731.32
Fig. 14:
Illustration of MK, MKA - installation depth 1000 mm, grease-lubricated
Table 16:
List of components
Part No.
Description
Part No.
Description
102
Volute casing
635
Grease cup
210
Shaft
68-3
Cover plate
230
Impeller
710.01
Pipe
303.01
Thrust and radial bearing
710.30
Pipe
303.02
Thrust and radial bearing
without vertical hole
712.01
13)
Support column without hole
321
Radial ball bearing
731.30/.31/.32
Pipe union
400.11/.12
Gasket
801
Flanged motor
411.11
Joint ring
81-39
Clamp
500.01
Ring
81-45
Float switch
502
Casing wear ring
901.01
Hexagon head bolt
520
Sleeve
902.01/.02/.12
Stud
545
Bearing bush
903.11
Screw plug
550.01/.11
Disc
920.01/.02/.11/.12
Nut
561.01/.02
Grooved pin
13)
Number of support columns 712 without hole, for installation depth ET: 1000 mm = 0; 1900 mm = 1; 2800 mm = 2