7 Servicing/Maintenance
38 of 64
MK
Lubrication by external fluid
DANGER
Failure of lubrication by external fluid
Explosion hazard!
▷
Monitor lubrication by external fluid.
DANGER
Risk of potentially explosive atmosphere by mixing of incompatible fluids in the
auxiliary piping
Risk of burns!
Explosion hazard!
▷
Make sure that the barrier fluid or quench liquid are compatible with the fluid
handled.
For lubrication by external fluid provide a flushing water connection which meets the
following conditions:
▪
Maximum flushing water temperature: 40 °C
▪
Minimum pressure required: 2.5 bar
▪
Fit connection line with shut-off valve and non-return valve.
▪
Control by a solenoid valve connected in parallel with the motor is
recommended.