11.4 Diverter
One of the product improvements to the GIW LCC Expeller pumps is the addition of a Diverter to further
reduce the accumulation of solids in the expeller chamber. This is a urethane part that is pressed into the hub
area of the pump casing. See the LCC Maintenance Manual for specific pump disassembly procedures
.
Installation instructions:
Disable the driver to prevent pump operation
Drain the system and remove the suction pipe
Remove the suction liner and impeller
Clean the hub area of the pump casing
Removal of the pump casing will be necessary for the LCC 9 Metal & Rubber lined pumps, see figure
below.
Clean the face of the expeller hub
Position the Diverter with the tapered ring facing into the pump as shown below
Press the Diverter completely back against the expeller plate –
If necessary, seat the Diverter using a small hammer and a smooth wood block cut to fit between the lip
and casing
Place a small straight edge along the back of the pump casing to verify the diverter is flush to the casing
plane within 3 mm.
Place two (2) new impeller release gaskets on the shaft
Coat the shaft threads with anti-seize
Thread the impeller on the shaft and hand tighten
Reinstall the suction liner and adjust the impeller nose gap
Connect the suction piping and restart the pump