5 Installation at Site
26 of 62
Etanorm V
1228.87/01-EN
Size
Suction nozzle / discharge nozzle
DN
3
F
x
F
y
F
z
∑F
M
x
M
y
M
z
[N]
[N]
[N]
[N]
[Nm]
[Nm]
[Nm]
065-040-250
50
1000
830
1250
1803
650
320
500
065-040-315
50
1000
830
1250
1803
650
320
500
065-050-125
65
1300
1050
1600
2314
1050
550
790
065-050-160
65
1300
1050
1600
2314
1050
550
790
065-050-200
65
1300
1050
1600
2314
1050
550
790
065-050-250
65
1300
1050
1600
2314
1050
550
790
065-050-315
65
1300
1050
1600
2314
1050
550
790
080-065-125
80
1550
1300
1950
2810
1350
690
1000
080-065-160
80
1550
1300
1950
2810
1350
690
1000
080-065-200
80
1550
1300
1950
2810
1350
690
1000
080-065-250
80
1550
1300
1950
2810
1350
690
1000
080-065-315
80
1550
1300
1950
2810
1350
690
1000
100-080-160
100
2000
1600
2500
3579
1850
900
1400
100-080-200
100
2000
1600
2500
3579
1850
900
1400
100-080-250
100
2000
1600
2500
3579
1850
900
1400
100-080-315
100
2000
1600
2500
3579
1850
900
1400
100-080-400
100
2000
1600
2500
3579
1850
900
1400
125-100-160
125
2700
2200
3400
4867
2550
1300
1900
125-100-200
125
2700
2200
3400
4867
2550
1300
1900
125-100-250
125
2700
2200
3400
4867
2550
1300
1900
125-100-315
125
2700
2200
3400
4867
2550
1300
1900
125-100-400
125
2700
2200
3400
4867
2550
1300
1900
150-125-200
150
3450
2850
4300
6206
3150
1600
2450
150-125-250
150
3450
2850
4300
6206
3150
1600
2450
150-125-315
150
3450
2850
4300
6206
3150
1600
2450
150-125-400
150
3450
2850
4300
6206
3150
1600
2450
200-150-200
200
5250
4300
6750
9572
4850
2450
3550
200-150-250
200
5250
4300
6750
9572
4850
2450
3550
200-150-315
200
5250
4300
6750
9572
4850
2450
3550
200-150-400
200
5250
4300
6750
9572
4850
2450
3550
5.5 Electrical connection
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷
Always have the electrical connections installed by a trained electrician.
▷
Observe regulations IEC 60364 and, for explosion-proof versions, BS 60079 .
WARNING
Incorrect connection to the mains
Damage to the power supply network, short circuit!
▷
Observe the technical specifications of the local energy supply companies.
1. Check the available mains voltage against the data on the name plate.
2. Select an appropriate start-up method.