4.5 Design details
Design
▪
Volute casing pump
▪
For vertical installation in closed tanks under atmospheric pressure
▪
Single-stage
▪
Ratings to EN 733
▪
Rigid connection between pump and motor
Pump casing
▪
Radially split volute casing
Stainless steel variant / grey cast iron variant for design with shaft unit WS 55:
▪
Volute casing with integrally cast pump feet
▪
Replaceable casing wear rings
Drive
▪
KSB surface-cooled IEC three-phase current squirrel-cage motor
▪
Type of construction IM V1
▪
Rated voltage (50 Hz) 220-240 V / 380-420 V ≤ 2.20 kW
▪
Rated voltage (50 Hz) 380-420 V / 660 - 725 V ≥ 3.00 kW
▪
Rated voltage (60 Hz) 440-480 V ≤ 2.60 kW
▪
Rated voltage (60 Hz) 440-480 V ≥ 3.60 kW
▪
Enclosure IP55
▪
Thermal class F with temperature sensor, 3 PTC thermistors
▪
Duty type: continuous duty S1
Contact guard
Design D:
▪
Cover plates at bearing lantern to EN 294
Design W:
▪
Cover plates at drive lantern to EN 294
Shaft seal
▪
Controlled gap
Impeller type
▪
Closed radial impeller with multiply curved vanes
Bearings
Design D:
▪
Deep groove ball bearings greased for life in a bearing lantern above the cover
plate, pump shaft cantilevered below the cover plate
Design W:
▪
Product-lubricated SiC/SiC plain bearing (pump end), rigid coupling between
pump shaft and motor shaft
Automation
Automation options:
▪
PumpDrive
▪
KSB SuPremE
▪
Efficiency class IE4/IE5 to IEC TS 60034-30-2:2016