5 Installation at Site
21 of 76
EtaLine Pro
1168.87/01-EN
5 Installation at Site
5.1 Safety regulations
DANGER
Installation in potentially explosive atmospheres
Explosion hazard!
▷
Never install the pump in potentially explosive atmospheres.
▷
Observe the information given in the data sheet and on the name plates of the
pump system.
DANGER
Use for drinking water or foodstuff applications
Danger of poisoning!
▷
Never use the pump for drinking water or foodstuff applications.
CAUTION
Improper installation of the pump set
Damage to the pump set!
▷
Observe the permissible ambient conditions and the pump set’s type of
enclosure.
▷
Observe the permissible ambient temperatures. Ambient temperatures < 0 °C
are not permitted.
▷
In the event of outdoor installation, fit a protective roof to protect the pump
set from the weather (e. g. sun, rain, snow).
5.2 Checks to be carried out prior to installation
Foundation
Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
CAUTION
Ingress of leakage into the motor
Damage to the pump!
▷
Never install the pump set with the "motor below".
Protective roof Protective roof/additional roofing
For vertical installation, fit a protective roof or additional roofing on site to prevent
foreign objects from falling into the fan hood.
Ventilation Ventilation
WARNING
Improper installation
Drive overheated!
▷
Maintain the specified minimum distances to neighbouring assemblies.
▷
Never restrict the ventilation ducting to/from the drive.
▷
Prevent exhaust air from neighbouring assemblies from being drawn in directly.