3 Transport/Storage/Disposal
13 of 76
EtaLine Pro
1168.87/01-EN
CAUTION
Improper placing down of pump sets
Damage to the pump set!
▷
Never place down the pump set with its axis in a vertical position.
Fig. 2:
Placing down the pump set
Ambient conditions for transport
(IEC 60721-3-2, EN 50178)
▪
Climatic conditions for transport: Class 2K3
▪
Temperature range: -25 °C to +70 °C
▪
Relative humidity: < 95 %
▪
Condensation must be prevented.
▪
Atmospheric pressure: 70 KPa to 106 KPa
3.3 Storage/preservation
CAUTION
Damage during storage due to humidity, dirt or vermin
Corrosion/contamination of pump (set)!
▷
For outdoor storage cover the pump (set) and accessories with waterproof
material and protect against condensation.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage to the pump!
▷
Clean and cover pump openings and connections as required prior to putting
the pump into storage.
If commissioning is to take place some time after delivery, we recommend that the
following measures be taken for pump (set) storage.
Store the pump (set) in a dry, protected room where the atmospheric humidity is as
constant as possible.
Storage of new pump sets:
New pump sets are delivered duly prepared for storage. If properly stored indoors,
the equipment is protected for a maximum of 12 months.
Storage of pump sets that have previously been operated:
When storing a pump set that has already been operated, observe the
(