8 Trouble-shooting
26 of 32
Calio-Therm S NC/NCV
8 Trouble-shooting
WARNING
Improper work to remedy faults
Risk of injury!
▷
For any work performed to remedy faults, observe the relevant information
given in this operating manual and/or in the product literature provided by the
accessories manufacturer.
If problems occur that are not described in the following table, consultation with the
KSB
customer service is required.
A
Pump is running, but does not deliver
B
Pump does not start up or pump running irregularly
C
Pump running but not delivering water
D
Noises during pump operation
Table 9:
Trouble-shooting
A B C D Possible cause
Remedy
1)
✘
-
-
- Pump not connected to power supply
Check the power supply and fuses or
reset the voltage (interrupt and re-establish
power supply).
✘
-
-
- Pump blocked (e.g. due to contamination)
✘
-
-
- Defective motor
Replace the pump.
-
✘
-
- Impurities in the pump
See section on maintenance.
-
-
✘
- Air in the system
Vent the system and the pump.
-
-
✘
- Gate valve closed
Open the gate valve.
-
-
-
✘
Excessive pump power output
Select a lower speed level.
-
-
-
✘
System pressure too low
Increase the system pressure by filling more water
into the boiler.
-
-
-
✘
Air in the system
Vent the pump and piping.
1)
Release pump pressure before attempting to remedy faults on parts which are subjected to pressure.